![Dell P92F Service Manual Download Page 24](http://html.mh-extra.com/html/dell/p92f/p92f_service-manual_83866024.webp)
Steps
1. Align the notch on the solid-state drive with the tab on the SSD1 slot.
2. Slide the solid-state drive into the SSD1 slot.
3. Using the alignment post, place the solid-state drive thermal bracket over the solid-state drive.
4. Align the screw hole on the solid-state drive thermal bracket with the screw hole on the system board.
5. Replace the screw (M2x4) that secures the solid-state drive thermal bracket and the solid-state drive to the system board.
Next steps
1. Install the
.
2. Install the
After working inside your computer
.
Solid-state drive in SSD2 slot
Removing the M.2 2230 solid-state drive from the SSD2 slot
Prerequisites
Before working inside your computer
.
2. Remove the
.
3. Remove the
.
About this task
NOTE:
This procedure applies only to computers shipped with an M.2 2230 solid-state drive installed in the SSD2 slot.
NOTE:
Depending on the configuration ordered, your computer may support an M.2 2230 solid-state drive or an M.2 2280
solid-state drive in SSD2 slot.
The following image indicates the location of the M.2 2230 solid-state drive that is installed in the SSD2 slot and provides a
visual representation of the removal procedure.
24
Removing and installing components