System ambient after altitude
derating (°C)
Maximum supported power
dissipation (W) for 85°C or
above still air rated PCIe
cards
Maximum supported power
dissipation (W) for 70°C still
air rated PCIe cards
Maximum supported power
dissipation (W) for 55°C still
air rated PCIe cards
20
15
12
8
25
14
10
6
30
13
9
5
35
12
8
4
40
10
6
3
45
9
5
2
50
8
4
1
55
6
3
Not supported
60
5
2
Not supported
65
4
1
Not supported
70
3
Not supported
Not supported
NOTE: PCIe cards must support still air environment and must not require active cooling.
NOTE: PCIe cards rated above 25 W are not supported regardless of temperature rating.
NOTE: If a PCIe card is rated at a temperature that is not shown in the table, use interpolation to calculate the maximum
supported power.
NOTE: If a PCIe card is rated at a temperature greater than 85°C, it shall be treated as an 85°C rated card in
determining the supported power.
Environmental conditions - Power module
Environmental requirements
Ingress protection rating
IP50
Temperature range:
Operating (with a maximum temperature gradation of
15°C per hour)
•
-30°C to 70°C (-22°F to 158°F) when connected to a 24V
AC/DC power source.
•
0°C to 40°C (-22°F to 104°F) when connected to a power
adapter or battery.
NOTE: The maximum operating temperature is derated
1°C/305m(1000ft) above sea level altitude.
Non-operating
-40°C to 85°C (-40°F to 185 °F)
Relative humidity (maximum):
Operating (with maximum humidity gradation of 10%
per hour)
10% to 90% (non-condensing)
Non-operating ((with maximum humidity gradation of
10% per hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating
-15.2m to 5000m (-50ft to 16,404ft)