Environmental requirements
NOTE: The maximum operating temperature is derated
1°C/305m (1000ft) above sea level altitude.
Storage
-15.20 m to 10,668 m (-50 ft to 35,000 ft)
Environmental conditions - Enclosure
Ingress protection rating
IP65
NOTE: Require IP65 or above conduit connection.
Temperature range:
Operating (with a maximum temperature gradation of
15°C per hour)
•
Edge Gateway 5000: 0°C to 45°C (32°F to 113°F)
•
Edge Gateway 5100: -30°C to 70°C (-22°F to 158°F)
NOTE: The maximum operating temperature is derated
1°C/305 m (1000 ft) above sea level altitude.
NOTE: The maximum operating temperature is derated
18°C (32.4°F) under direct solar thermal load.
Non-operating (with a maximum temperature gradation
of 15°C per hour)
-40°C to 85°C (-40°F to 185 °F)
Relative humidity (maximum):
Operating (with maximum humidity gradation of 10%
per hour)
10% to 90% (non-condensing)
Non-operating (with maximum humidity gradation of
10% per hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating
-15.2 m to 5000 m (-50 ft to 16,404 ft)
NOTE: The maximum operating temperature is derated
1°C/305 m (1000 ft) above sea level altitude.
Storage
-15.2 m to 10,668 m (-50 ft to 35,000 ft)
Operating conditions
Maximum vibration
5000
5100
Operational
1.54 Grms, 15 min/side
1.54 Grms, 60 min/side
Maximum shock
5000
5100
Operational
40G, 2ms
40G, 2ms
Non-operational
160g, 2ms Half Sine Shock
160g, 2ms Half Sine Shock