Error Code Message Information
PSU0035
Message
An over voltage fault detected on power supply <
number
>.
LCD Message Over voltage fault on PSU <
number
>. Check PSU.
Action
Check input power or reinstall the power supply. If the issue persists, see
Getting Help
.
PSU0036
Message
An over current fault detected on power supply <
number
>.
LCD Message An over current fault detected on PSU <
number
>. Check PSU.
Details
This failure may be the result of an electrical issue with cables or subsystem
components in the system.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for damage.
3. If the issue persists, see
Getting Help
.
PSU0037
Message
Fan failure detected on power supply <
number
>.
LCD Message
Fan failure detected on PSU <
number
>. Check PSU.
Action
Check for fan blockage. If the problem persists, see
Getting Help
.
PSU0076
Message
A power supply wattage mismatch is detected; power supply <
number
> is rated for
<
value
> watts.
LCD Message PSU wattage mismatch; PSU <
number
> = <
value
>watts
Details
Power supplies should be of the same input type and power rating.
Action
Install matched power supplies and review this manual for proper configuration.
PSU1201
Message Power supply redundancy is lost.
Details
The power supply tries to operate in a degraded state. System Performance and power
redundancy may be degraded or lost.
Action
Check input power. Reinstall the power supply. If the issue persists, see
Getting Help
.
PSU1204
Message
The power supplies are not redundant. Insufficient resources to maintain normal
operations.
LCD Message PSU redundancy degraded. Check PSU cables.
Details
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
Action
Check the event log for power supply failures. Review system configuration and power
consumption.
PWR1004
Message The system performance degraded because power capacity has changed.
Details
The system may power down or operate in a performance degraded state.
131