282
BigIron RX Series Configuration Guide
53-1002253-01
Configuration considerations
10
Configuration considerations
•
The feature is supported only on Ethernet ports.
•
To configure UDLD on a trunk group, you must configure the feature on each port of the group
individually. Configuring UDLD on a trunk group’s primary port enables the feature on that port
only.
•
Dynamic trunking is not supported. If you want to configure a trunk group that contains ports
on which UDLD is enabled, you must remove the UDLD configuration from the ports. After you
create the trunk group, you can re-add the UDLD configuration.
Configuring UDLD
To enable UDLD on a port, enter a command such as the following at the global CONFIG level of the
CLI.
BigIron RX(config)# link-keepalive ethernet 1/1
Syntax: [no] link-keepalive ethernet
<slot>
/
<portnum>
[ethernet
<slot>
/
<portnum>
]
To enable the feature on a trunk group, enter commands such as the following.
BigIron RX(config)# link-keepalive ethernet 1/1 ethernet 1/2
BigIron RX(config)# link-keepalive ethernet 1/3 ethernet 1/4
These commands enable UDLD on ports 1/1 – 1/4. You can specify up to two ports on the same
command line.
Changing the keepalive interval
By default, ports enabled for UDLD send a link health-check packet once every 500 ms. You can
change the interval to a value from 1 – 60, where 1 is 100 ms, 2 is 200 ms, and so on. To change
the interval, enter a command such as the following.
BigIron RX(config)# link-keepalive interval 3
Syntax: [no] link-keepalive interval
<num>
The
<num>
parameter specifies how often the ports send a UDLD packet. You can specify from 1
– 60, in 100 ms increments. The default is 5 (500 ms).
Changing the keepalive retries
You can change the maximum number of keepalive attempts to a value from 3 – 10. To change the
maximum number of attempts, enter a command such as the following.
BigIron RX(config)# link-keepalive retries 4
Syntax: [no] link-keepalive retries
<num>
The
<num>
parameter specifies the maximum number of times the port will try the health check.
You can specify a value from 3 – 10. The default is 5.
Summary of Contents for BigIron RX Series
Page 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Page 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Page 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Page 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Page 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Page 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Page 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Page 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Page 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Page 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Page 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Page 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Page 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Page 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Page 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Page 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Page 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Page 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Page 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Page 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Page 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Page 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...