Configuring Uni-Directional Link Detection (UDLD)
This chapter describes configuring Uni-Directional Link Detection.Uni-directional Link Detection
(UDLD) monitors a link between two BigIron RX devices and provides a fast detection of link
failures. UDLD brings the ports on both ends of the link down if the link goes down at any point
between the two devices. This feature is useful for links that are individual ports and for trunk links.
Figure 20
shows an example.
FIGURE 20
UDLD example
Ports enabled for UDLD exchange proprietary health-check packets once every 500 ms (the
keepalive interval). If a port does not receive a health-check packet from the port at the other end
of the link within the keepalive interval, the port waits for two more intervals. If the port still does
not receive a health-check packet after waiting for three intervals, UDLD will be kept in a
suspended state until it receives the first keep-alive message from the other end. In this
suspended state, UDLD will continue to send the keep-alive message but will not bring the port
down after maximum number of retries is done and no keep-alive message is received from the
other end. The UDLD will transition from this suspended state to active state after it receives the
first keep-alive message from the other end. In the active state, UDLD peers will continue to
exchange keep alive messages periodically and if there are keep-alive messages are missed for
certain number of times from the other end, UDLD will bring down the logical port. The UDLD will
then transition from active to suspended state.
Everytime UDLD is enabled on a port, the port will be transitioned into the suspended state to
detect if the other end (peer) supports UDLD. This include the case where:
•
User enables UDLD on a port
•
A port that has UDLD enabled coming back up after an system reboot
•
Port was brought down by UDLD after uni-directional link was detected and now the problem is
fixed.
X
Without link keepalive, the ports remain
enabled. Traffic continues to be load balanced to the
ports connected to the failed link.
When link keepalive is enabled, the feature
brings down the ports connected
to the failed link.
Summary of Contents for BigIron RX Series
Page 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Page 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Page 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Page 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Page 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Page 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Page 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Page 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Page 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Page 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Page 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Page 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Page 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Page 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Page 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Page 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Page 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Page 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Page 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Page 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Page 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Page 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...