Power requirements
Terminal block connector input voltage/
current
24 VAC (50 Hz–60 Hz) or 24 VDC / 15A
Power adapter input voltage/current
19.5 VDC / 6.67A
Battery connector port
12VDC / 15A
Environmental requirements
Ingress Protection Rating
IP50
Temperature range:
Operating (with a maximum
temperature gradation of 15°C per
hour)
• -30°C to 70°C (-22°F to 158°F) when
connected to a 24V AC/DC power
source.
• -30°C to 40°C (-22°F to 104°F) when
connected to a power adapter or
battery.
NOTE:
The maximum operating
temperature is derated 1°C/
305m(1000ft) above sea level
altitude.
Non-operating
-40°C to 70 °C (-40°F to 158°F)
Relative humidity (maximum):
Operating (with maximum
humidity gradation of 10% per
hour)
10% to 90% (non-condensing)
Non-operating ((with maximum
humidity gradation of 10% per
hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating
-15.2m to 5000m (-50ft to 16,404ft)
NOTE:
The maximum operating
temperature is derated 1°C/305m
(1000ft) above sea level altitude.
Power Module Overview
50
Summary of Contents for 5000 Series
Page 21: ...4 Secure the Dell Edge Gateway by pressing the latch Setting up your Dell Edge Gateway 21 ...
Page 26: ...The Wind River operating system is setup Setting up your operating system 26 ...
Page 31: ...Features I O Module Overview 31 ...