Configure BMC Management address on BMC
console
From the BMC console, run the following commands:
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 ipsrc <static or dhcp>
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 ipaddr xxx.xx.xxx.xx
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 netmask 255.255.255.0
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 defgw ipaddr xxx.xx.xxx.254
Run the Unified Firmware Updater from a Linux
server
1. Deploy a Linux OS (CentOS, RedHat, Ubuntu) that connects to the VEP4600 BMC network. Can be a VM based Linux server.
2. Verify you can reach the BMC ip address with ipmitool:
test@LinuxVM:~/UFW$ ipmitool -I lanplus -H xxx.xx.xx.xxx -U admin -P admin power status
Chassis Power is on
3. Run the UFW from the Linux server with the following command:
./vep4600_ufw_x.x
<BMC IP address> interactive
test@LinuxVM:~/UFW$ ./vep4600_ufw_x.x xxx.xx.xxx.xx interactive
Creating directory temp
Verifying archive integrity... 100% MD5 checksums are OK. All good.
Uncompressing release 100%
./start.sh: line 20: sh_ver: command not found
firmware_updater/
firmware_updater/VEP4600-BIOS-3.41.0.9-15.BIN
firmware_updater/AZUL_CPLD_V10_refresh.vme
firmware_updater/libcrypto.so.1.0.0
firmware_updater/ipmitool
firmware_updater/AZUL_CPLD_V10_norefresh.vme
firmware_updater/mstr_01_20181226.vme
firmware_updater/MCCARD_mstr_cpld_00_02_201809101600.vme
firmware_updater/libcrypto.so.1.1
firmware_updater/x520/
firmware_updater/x520/Intel_Proprietary_License.pdf
firmware_updater/x520/PIEConfig.sh
firmware_updater/x520/smbiosHelp.txt
firmware_updater/x520/UpdRollBack.lst
firmware_updater/x520/spUtilityHelp.txt
firmware_updater/x520/sagepond_map.txt
firmware_updater/x520/payload/
firmware_updater/x520/payload/BootIMG.CFB
firmware_updater/x520/payload/FmpUpdateWrapper.efi
firmware_updater/x520/PIEInfo.txt
firmware_updater/x520/os_mapping.xml
firmware_updater/x520/en.prop
firmware_updater/x520/duppmdatacollector.bin
firmware_updater/x520/nvmupdate.cfg
firmware_updater/x520/nvmupdate64e
firmware_updater/x520/package.xml
firmware_updater/x520/nvminv.cfg
firmware_updater/x520/BootIMG.FLB
firmware_updater/x520/vpd.txt
firmware_updater/x520/LinuxDepWrapperLinux.bin
firmware_updater/x520/svmExeMsg.xsl
firmware_updater/x520/Version.txt
firmware_updater/x520/uni-eol.txt
firmware_updater/x520/buildVer.sh
Upgrade Firmware through BMC
23
Summary of Contents for 210-APGV
Page 1: ...VEP4600 Operating System Installation Guide March 2020 ...
Page 9: ...VEP4600 start up and serial console connection 9 ...
Page 40: ...40 Configure BIOS and Install RHEL OS ...
Page 41: ...Configure BIOS and Install RHEL OS 41 ...
Page 44: ...2 The installation process begins 44 Configure BIOS and Install RHEL OS ...
Page 48: ...7 Enter the root credentials and verify 48 Configure BIOS and Install RHEL OS ...
Page 59: ...Boot up screen Configure BIOS and Install Ubuntu OS 59 ...