Figure 12. Hardware Alert Identifying the Expansion Enclosure with the Failed Cooling Fan
5. In the
Hardware
tab navigation pane, expand the expansion enclosure identified in the previous step.
6. Select
Cooling Fan Sensors
. The status of each cooling fan is displayed in the
Cooling Fans
tab.
7. Select the failed cooling fan. The location of the failed cooling fan is displayed in the
Fan View
tab.
Figure 13. Rear View of the Expansion Enclosure Showing the Failed Cooling Fan
Replace a Power Supply/Cooling Fan Module
Use this procedure to replace a failed power supply/cooling fan module.
Prerequisites
Use SupportAssist to send diagnostic data to Dell Technical Support Services.
About this task
You can replace power supply/cooling fan modules one at a time without shutting down the storage system.
20