![Dell EMC SCv2000 Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/dell-emc/scv2000/scv2000_owners-manual_2468374012.webp)
Item
Control/Feature
Icon
Description
2
Battery fault indicator
•
Off – No faults
•
Blinking amber – Correctable fault detected
•
Steady amber – Uncorrectable fault detected; replace battery
3
MGMT port (Slot 3/Port 1)
—
Ethernet/iSCSI port that is typically used for storage system management and
access to the BMC
NOTE:
To use the MGMT port as an iSCSI port for replication to another
Storage Center, a Flex Port license and replication license are required.
To use the MGMT port as a front-end connection to host servers, a Flex
Port license is required.
4
REPL port (Slot 3/Port 2)
—
Ethernet/iSCSI port that is typically used for replication to another Storage Center
NOTE:
To use the RELP port as a front-end connection to host servers,
a Flex Port license is required.
5
SAS activity indicators
—
There are four SAS PHYs per SAS port.
•
Off – SAS PHY is not connected
•
Steady green – SAS PHY is connected, but not active
•
Blinking green – SAS PHY is not connected nor active
6
Storage controller status
On – Storage controller completed a power-on self-test (POST)
7
Recessed power off button
Not currently used
8
Storage controller fault
•
Off – No faults
•
Steady amber – Firmware has detected an error
•
Blinking amber – Storage controller is performing a POST
9
Recessed reset button
Not currently used
10
Identification LED
•
Off – Identification disabled
•
Blinking blue (for 15 sec.) – Identification is enabled
•
Blinking blue (continuously) – Storage controller shut down to the Advanced
Configuration and Power Interface (ACPI) S5 state
11
USB port
One USB 3.0 connector
12
Diagnostic LEDs (8)
—
•
Green LEDs 0–3 – Low byte hex POST code
•
Green LEDs 4–7 – High byte hex POST code
13
Serial port (3.5 mm mini jack)
Not for customer use
14
Two options:
•
Four iSCSI ports (Slot 1/Port
1, Slot 1/Port 2, Slot 1/Port
3, and Slot 1/Port 4) with
two LEDs per port
•
Two iSCSI ports (Slot 1/Port
1 and Slot 1/Port 2) with two
LEDs per port
—
•
Off – power
•
Steady Amber – Link
•
Blinking Green – Activity
15
Mini-SAS port B (Slot 2/Port 2)
Back-end expansion port B
16
Mini-SAS port A (Slot 2/Port 1)
Back-end expansion port A
12
About the SCv2000/SCv2020 Storage System