Table 29. Terminal emulator display settings
Parameter
Value
Terminal emulation mode
VT-100 or ANSI (for color support)
Font
Terminal
Translations
None
Columns
80
Table 30. Terminal emulator connection settings
Parameter
Value
Connector
COM3 (for example)
1,2
Baud rate
115,200
Data bits
8
Parity
None
Parmaeter
Value
Stop bits
1
Flow control
None
1
Your server or laptop configuration determines which COM port is used for Disk Array USB Port.
2
Verify the appropriate COM port for use with the CLI.
3
In the terminal emulator, connect to controller A.
4
Press
Enter
to display the CLI prompt (#).
The CLI displays the system version, Management Controller version, and login prompt
a
At the login prompt, enter the default user
manage
.
b
Enter the default password
!manage
If the default user or password—or both—have been changed for security reasons, enter the secure login credentials instead of the
defaults shown above.
Mini-USB Device Connection
Emulated serial port
Once attached to the controller module, the management computer should detect a new USB device. Using the Emulated Serial Port
interface, the ME4 Series controller presents a single serial port using a
customer vendor ID
and
product ID
. Effective presentation of the
emulated serial port assumes the management computer previously had terminal emulator installed. See also
Serial port configuration is unnecessary.
IMPORTANT:
Certain operating systems require a device driver or special mode of operation to enable proper functioning of the
Device Driver special operations mode
.
142
Connecting through the CLI port using a serial cable