Number
Severity
Description/Recommended actions
•
No action is required.
505
Warning
The indicated virtual pool was created with a size smaller than 500 GB, which can lead to unpredictable
behavior.
The storage system may not perform correctly.
Recommended actions:
•
Add disk groups to the virtual pool to increase the size of the pool.
506
Info.
Addition of the indicated disk group was started.
When this operation is complete, event 467 is logged.
Recommended actions:
•
No action is required.
507
Info.
The link speed of the indicated disk does not match the link speed that the enclosure is capable of.
This event is logged when the auto-negotiated link speed is less than the maximum speed that the enclosure
supports. The disk is functional, but I/O performance is reduced. This event may be logged for one disk
channel or for both disk channels.
Recommended actions:
•
If the disk is a member of a non-fault-tolerant disk group (RAID 0 or non-RAID), move the data to a
different disk group.
•
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the same or greater
capacity. For continued optimum I/O performance, the replacement disk should have performance that is
the same as or better than the one it is replacing.
508
Error
The indicated virtual pool went offline. All of its volumes also went offline.
All data in the virtual pool has been lost. This condition can be caused by corrupt or inaccessible virtual pool
metadata.
Recommended actions:
•
Check for other events that indicate faults in the system and follow the recommended actions for those
events.
•
Re-create the virtual pool.
•
Restore the data from a backup, if available.
509
Error
The metadata volume for the indicated virtual pool went offline. Volume mappings and persistent reservations
are inaccessible or lost.
Recommended actions:
•
Check for other events that indicate faults in the system and follow the recommended actions for those
events.
•
Create new mappings for the volumes. Persistent reservations will be restored by host systems
automatically.
510
Info.
The FDE lock key has been set or changed by a user.
Recommended actions:
•
Be sure to record the lock key passphrase and the new lock ID.
511
Info.
The FDE import lock key has been set by a user.
Events and event messages