Number
Severity
Description/Recommended actions
Recommended actions:
•
Manually enable write-back cache.
204
Error
An error occurred with either the NV device itself or the transport mechanism. The system may attempt to
recover itself.
The CompactFlash card is used for backing up unwritten cache data when a controller goes down
unexpectedly, such as when a power failure occurs. This event is generated when the Storage Controller (SC)
detects a problem with the CompactFlash as it is booting up.
Recommended actions:
•
Restart the Storage Controller that logged this event.
•
If this event is logged again, shut down the Storage Controller and replace the CompactFlash.
•
If this event is logged again, shut down the Storage Controller and replace the controller module.
Warning
The system has started and found an issue with the NV device. The system will attempt to recover itself.
The CompactFlash card is used for backing up unwritten cache data when a controller goes down
unexpectedly, such as when a power failure occurs. This event is generated when the Storage Controller (SC)
detects a problem with the CompactFlash as it is booting up.
Recommended actions:
•
Restart the Storage Controller that logged this event.
•
If this event is logged again, shut down the Storage Controller and replace the controller module.
Info.
The system has come up normally and the NV device is in a normal expected state.
This event will be logged as an Error or Warning event if any user action is required.
Recommended actions:
•
No action is required.
205
Info.
The indicated volume has been mapped or unmapped.
Recommended actions:
•
No action is required.
206
Info.
Disk group scrub has started.
The scrub checks disks in the disk group for the following types of errors:
•
Data parity errors for a RAID 3, 5, 6, or 50 disk group.
•
Mirror verify errors for a RAID 1 or RAID 10 disk group.
•
Media errors for all RAID levels including RAID 0 and non-RAID disk groups.
When errors are detected, they are automatically corrected.
When the scrub is complete, event 207 is logged.
Recommended actions:
•
No action is required.
207
Error
Disk group scrub completed and found an excessive number of errors in the indicated disk group.
This event is logged as Error severity when more than 100 parity or mirror mismatches are found and
corrected during a scrub or when 1 to 99 parity or mirror mismatches are found and corrected during each of
10 separate scrubs of the same disk group.
100
Events and event messages