7. Restart the Data Domain system. As the system boots up, the HOST/
EXPANSION LEDs on the shelf controller ports that are connected to the SAS
I/O module in the Data Domain system change from off to blue or green.
If any of these LEDs stays off or is not running at normal speed, it means there
is a problem in the connection between the system and the shelf. See the
section
on page 11 for more information. Reseat or
replace the cable and check the LEDs again. If the connection still has a
problem, replace the controller module or the SAS I/O module.
Verifying shelf installation
The Data Domain system recognizes all data storage (system and attached shelves) as
part of a single file system volume.
WARNING
l
Do not remove or disconnect a shelf that has been added earlier. If a shelf is
disconnected, the file system volume is immediately disabled and all data in
the volume is lost.
l
To re-enable a shelf, reconnect the shelf or transfer the disks from the shelf
to another empty shelf chassis and connect.
l
If the data on a shelf is not available to the file system volume, the volume
cannot be recovered.
l
Unless the same disks are available to the file system, the DD OS must be re-
installed as directed by your contracted service provider or Online Support
site,
.
Procedure
1. After installing the new shelves, check the status of the SAS I/O module by
entering the
disk port show summary
command:
#
disk port show summary
Port Connection Link Connected Status
Type Speed Enclosure IDs
---- ---------- ------- ------------- -------
5a SAS offline
5b SAS offline
5c SAS offline
5d SAS offline
6a SAS offline
6b SAS offline
6c SAS offline
6d SAS offline
7a SAS 24 Gbps 5 online
7b SAS 24 Gbps 6 online
7c SAS 24 Gbps 4 online
7d SAS 24 Gbps 2, 3 online
8a SAS 24 Gbps 5 online
8b SAS 24 Gbps 6 online
8c SAS 24 Gbps 4 online
8d SAS 24 Gbps 2, 3 online
The output shows:
l
The
offline
status for each SAS connection, such as
5a
,
5b
,
5c
, and so
on.
Post-Installation Tasks
Verifying shelf installation
89
Summary of Contents for Data Domain DS60
Page 1: ...Dell EMC Data Domain DS60 Expansion Shelf Hardware Guide 302 002 100 REV 05 ...
Page 4: ...Hardware specifications 100 CONTENTS 4 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 8: ...Revision history 8 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 43: ...Figure 19 DD6300 Installing the Shelves DD6300 DD6800 and DD9300 cabling 43 ...
Page 80: ...Installing the Shelves 80 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 98: ...Post Installation Tasks 98 Data Domain DS60 Expansion Shelf Hardware Guide ...