Figure 55 Location of NVRAM and I/O modules (continued)
Note
Slots 2, 3, and 6 (three I/O slots) are used for SAS I/O modules for systems without
Extended Retention (ER).
Note
Slots 2, 3, 6, and 9 (four I/O slots) are for SAS I/O modules for systems with ER or
DD Cloud Tier software.
The table shows the I/O module slot assignments for the DD9500 and DD9800
systems. Each type of I/O module is restricted to certain slots.
The I/O module slot assignments for the DD9500 and DD9800 systems are the same.
Table 16 DD9500 and DD9800 I/O module slot assignments
Slot
Base
configuratio
n
HA
ER or DD Cloud
Tier
DD Cloud Tier
and HA
0
NVRAM
NVRAM
NVRAM
NVRAM
1
Fibre Channel
(FC), Ethernet
or empty
Fibre Channel
(FC), Ethernet
or empty
Fibre Channel (FC),
Ethernet or empty
Fibre Channel (FC),
Ethernet or empty
2
SAS
SAS
SAS
SAS
3
SAS
SAS
SAS
SAS
4
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
5
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
6
SAS
SAS
SAS
SAS
7
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
8
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
9
Not available
(contains a
filler)
Not available
(contains a
filler)
SAS
SAS
10
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
11
FC, Ethernet or
empty
10 Gb optical
Ethernet for
interconnect
between the
primary and
FC, Ethernet or
empty
10 Gb optical
Ethernet for
interconnect
between the
primary and standby
Data Domain-Specific Installation
I/O module slot assignments
85
Summary of Contents for Data Domain DS60
Page 1: ...Dell EMC Data Domain DS60 Expansion Shelf Hardware Guide 302 002 100 REV 05 ...
Page 4: ...Hardware specifications 100 CONTENTS 4 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 8: ...Revision history 8 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 43: ...Figure 19 DD6300 Installing the Shelves DD6300 DD6800 and DD9300 cabling 43 ...
Page 80: ...Installing the Shelves 80 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 98: ...Post Installation Tasks 98 Data Domain DS60 Expansion Shelf Hardware Guide ...