![Dell EMC Data Domain DS60 Hardware Manual Download Page 26](http://html.mh-extra.com/html/dell-emc/data-domain-ds60/data-domain-ds60_hardware-manual_2468170026.webp)
Figure 6 Shelf Cabling Connections
Note
SAS I/O cards are labeled on the back of the DD9500. The ports are labeled 0,1,
2, and 3. Cabling for each port is represented by a different color.
Requirements for combining DS60 and ES30 shelves
Note
ES20 shelves are only allowed to be connected to DD6300, DD6800 and DD9300, and
DD9500 or DD9800 systems to migrate the data using the shelf migration software
feature in DD OS 5.7 or later releases.
Some of the DS60 configurations described in the following sections also include
ES30 shelves for DD Cloud Tier metadata, or FS15 shelves for HA.
Note
For HA pairs that have one or more ES30/FS15 shelves, the primary and standby
nodes use different cables to connect to ES30/FS15 shelves. The primary node uses
ES30/FS15 HOST (circle) connections, and the standby node uses ES30/FS15
EXPANSION (diamond) connections.
Installing the Shelves
26
Data Domain DS60 Expansion Shelf
Hardware Guide
Summary of Contents for Data Domain DS60
Page 1: ...Dell EMC Data Domain DS60 Expansion Shelf Hardware Guide 302 002 100 REV 05 ...
Page 4: ...Hardware specifications 100 CONTENTS 4 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 8: ...Revision history 8 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 43: ...Figure 19 DD6300 Installing the Shelves DD6300 DD6800 and DD9300 cabling 43 ...
Page 80: ...Installing the Shelves 80 Data Domain DS60 Expansion Shelf Hardware Guide ...
Page 98: ...Post Installation Tasks 98 Data Domain DS60 Expansion Shelf Hardware Guide ...