background image

Safety Notices

n

Warning

Read this manual thoroughly before operating, installing 

or performing maintenance on the equipment. Failure 

to follow instructions in this manual can cause property 

damage, injury or death.

 DANGER

Failure to disconnect the power at the main power 

supply disconnect could result in serious injury or death. 

The power switch DOES NOT disconnect all incoming 

power. 

 DANGER

Do not install or operate equipment that has been 

misused, abused, neglected, damaged, or altered/

modified from that of original manufactured 

specifications.

 DANGER

All utility connections and fixtures must be maintained 

in accordance with local and national codes.

 DANGER

Serious injury or death can occur from inhaling high 

concentrations of refrigerant vapors. These vapors also 

reduce oxygen levels in confined areas. Contact with 

liquid can cause frostbite. All containers, equipment 

and hoses are under high pressure. Do not puncture or 

damage these components.

n

Warning

Use caution when handling metal surface edges of all 

equipment.

n

Warning

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision 

concerning use of the appliance by a person responsible 

for their safety. Do not allow children to play with this 

appliance.

n

Warning

Do not store or use gasoline or other flammable vapors 

or liquids in the vicinity of this or any other appliance. 

Never use flammable oil soaked cloths or combustible 

cleaning solutions, for cleaning.

n

Warning

This product contains chemicals known to the State 

of California to cause cancer and/or birth defects or 

other reproductive harm. Operation, installation, and 

servicing of this product could expose you to airborne 

particles of glasswool or ceramic fibers, crystalline 

silica, and/or carbon monoxide. Inhalation of airborne 

particles of glasswool or ceramic fibers is known to the 

State of California to cause cancer. Inhalation of carbon 

monoxide is known to the State of California to cause 

birth defects or other reproductive harm.

n

Warning

Authorized Service Representatives are obligated to 

follow industry standard safety procedures, including, 

but not limited to, local/national regulations for 

disconnection / lock out / tag out procedures for all 

utilities including electric, gas, water and steam.

n

Warning

DO NOT touch refrigeration lines inside units; some may 

exceed temperatures of 200°F (93.3°C).

n

Warning

Do not damage the refrigeration circuit when installing, 

maintaining or servicing the unit.

,

Caution

Maintenance and servicing work, other than cleaning as 

described in this manual, must be done by an authorized 

service personnel.

Notice

 

Proper installation, care and maintenance are 

essential for maximum performance and trouble-free 

operation of your equipment. Visit our website www.

mtwkitchencare.com for manual updates, translations, 

or contact information for service agents in your area.

Summary of Contents for Shelleyglas KFW-1-NU

Page 1: ...n before operating this equipment Fresh Solutions Fit For You FlexiWell Serving Lines Shelleybasic TM by Delfield Shelleyglas TM by Delfield Shelleysteel TM by Delfield Shelleyglas TM by Delfield Shel...

Page 2: ...Stabilizing 13 Leg Caster Installation 13 Accessory Installation 13 Self Contained Flexiwell Drop In Cabinet Dimentions 14 Section 4 Operation Heated and Refrigerated Combo Counter Operation 18 Heate...

Page 3: ...Table of Contents continued Part Number 9291544 07 20 3 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 4: ...use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Never use flammable oil soaked cloths or combustible cleaning solutions for cleaning nWarning This pro...

Page 5: ...WP N8686 FWP N86103 FWP Serial Number Location Always have the serial number of your unit available when calling for parts or service Serial numbers are printed on serial tags Serial tags are located...

Page 6: ...unters Shelleysteel 12 x20 Pan Capacity Hot Electrical Amps Nema Plug System Capacity Heat of Rejection R290 Charge Amount 1042G 1 120 208 240 6 3 14 20P 625 310 150g 1042H 2 120 208 240 12 5 14 20P 9...

Page 7: ...249kg KFW 5 NU SFW 5 NU 660lbs 299kg KFW 6 NU SFW 6 NU 720lbs 327kg FlexiWell Hot and Cold Combo Serving Counters Shelleysteel Weight 1042G 300lbs 136kg 1042H 380lbs 172kg 1042I 460lbs 209kg 1042J 55...

Page 8: ...FW 4 NU 75 191cm KFW 5 NU 96 244cm SFW 5 NU 92 134cm KFW 6 NU 138 351cm SFW 6 NU 108 274cm FlexiWell Hot and Cold Combo Serving Counters Model Length Depth Height 1042G 26 66cm 31 5 80cm 40 91cm 1042H...

Page 9: ...Section 2 Specifications Part Number 9291544 07 20 9 Dimensions Continued N8600 Series EcoMark 1042 Series...

Page 10: ...Specifications Section 2 10 Part Number 9291544 07 20 SFW ShelleySteel Series KFW ShelleyGlas Series...

Page 11: ...ounded A separate fuse circuit breaker must be provided for each unit The maximum allowable voltage variation is 10 of the rated voltage at equipment start up when the electrical load is highest Check...

Page 12: ...perate this equipment in outdoor areas Caution Do not position the air intake vent near steam or heat exhaust of another appliance Section 3 Installation The location selected for the equipment must m...

Page 13: ...side Leveling will insure proper door operation and removal of condensate Cabinets with casters must have the caster brake set so the cabinet cannot move Stabilizing It is very important that all legs...

Page 14: ...16cm 102 259cm E 25 64cm 25 64cm 25 64cm F 4 75 12cm Min 2 75 7cm Max 4 75 12cm G 2 7 25 18cm 14 25 36cm 21 25 54cm 2 21 25 54cm 2 Place the condensing unit through the counter cutout 3 Extend the tel...

Page 15: ...the condensing unit s finned coil Any restriction to the proper air flow will void the compressor warranty Louver measures 20 00 x 25 00 51cm x 64cm Louver Cutout Size is 18 50 x 22 50 47cm x 57cm typ...

Page 16: ...Installation Section 3 16 Part Number 9291544 07 20 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 17: ...ning All covers and access panels must be in place and properly secured before operating this equipment nWarning Damp or wet hands may stick to cold surfaces nWarning Never use sharp objects or tools...

Page 18: ...team and water usage set control at lowest setting that will maintain proper food temperature To reduce preheating time use hot water to fill the well If the same temperature settings for each well ar...

Page 19: ...tand by mode The display will read Off then a period Press the lower left button again for 5 seconds The display will read On The unit will then start up in normal cooling mode Operation Indication St...

Page 20: ...CFu using the up down arrows and push the stand by button lower left button to enter the display unit menu 6 F should be displayed indicating Fahrenheit Use the down arrow to change it to C for Celsiu...

Page 21: ...Section 4 Operation Part Number 9291544 07 20 21 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 22: ...unit Do not work underneath a raised unit without proper blocking Do not lift the unit more than necessary to remove the leg Lifting the unit too far can make the unit unstable nWarning Never use a hi...

Page 23: ...s steel breakdown are small pits and cracks If this has begun clean thoroughly and start to apply stainless steel cleaners in attempt to restore the steel Fiberglass can be polished to eliminate water...

Page 24: ...DELFIELD 980 SOUTH ISABELLA ROAD MOUNT PLEASANT MI 48858 800 733 8821 WWW DELFIELD COM 2019 Welbilt Inc except where explicitly stated otherwise All rights reserved Part Number 9291544 07 20...