Operation
Section 4
20
Part Number: 9291544 07/20
CHANGING DISPLAY FROM FAHRENHEIT TO CELSIUS
ON ERC112 CONTROL
1. Simultaneously hold the up and down arrows for
5 seconds to access menu for password protected
parameters.
2. Screen should temporarily flash
PAS
and then move to
a numeric screen.
3. Scroll to
187
using the up/down arrows and push the
stand-by button (lower left button) to enter.
4. Scroll to
dis
using the up/down arrows and push the
stand-by button (lower left button) to enter into the
display menu.
5. Scroll to
CFu
using the up/down arrows and push the
stand-by button (lower left button) to enter the display
unit menu.
6. -F
should be displayed indicating Fahrenheit. Use
the down arrow to change it to
-C
for Celsius and hit
the stand-by button (lower left button) to enter the
change.
7. Push the defrost button (upper left button) to move
out of the display unit menu.
8. Push the defrost button (upper left button) to move
out of the display menu and back to the normal display.
NOTE: For steps 7 and 8, display will return back to normal
display after 30 seconds of inactivity.
Look for more!
Delfield Bulletin SB_0065 goes into further step-by-
step instructions on how to adjust an ERC control from
Fahrenheit to Celsius with visuals each step.
Summary of Contents for Shelleyglas KFW-1-NU
Page 3: ...Table of Contents continued Part Number 9291544 07 20 3 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ...Installation Section 3 16 Part Number 9291544 07 20 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 21: ...Section 4 Operation Part Number 9291544 07 20 21 THIS PAGE INTENTIONALLY LEFT BLANK...