Installation
Section 3
14
Part Number: 9291544 07/20
SELF-CONTAINED FLEXIWELL DROP-IN UNITS
N8600-FWP
For any non-standard installation consult the factory.
1. Cabinet interior minimum dimensions:
Dimension
N8618-FWP
N8635-FWP
N8652-FWP
A
29.75"/76cm
42.5"/108cm
55.25"/140cm
B
29"/74cm
29"/74cm
29"/74cm
C
28"/71cm
28"/71cm
28"/71cm
D
17"/43cm
34"/86cm
51"/130cm
E
25"/64cm
25"/64cm
25"/64cm
F
4.75”/12cm
Min. 2.75”/7cm -
Max. 4.75”/12cm
G
7.25”/18cm
14.25”/36cm
21.25”/54cm
Dimension
N8669-FWP
N8686-FWP
N86103-FWP
A
68"/173cm
85"/216cm
102"/259cm
B
29"/74cm
29"/74cm
29"/74cm
C
28"/71cm
28"/71cm
28"/71cm
D
68"/173cm
85"/216cm
102"/259cm
E
25"/64cm
25"/64cm
25"/64cm
F
4.75”/12cm
Min. 2.75”/7cm -
Max. 4.75”/12cm
G
(2) 7.25”/18cm
14.25”/36cm
21.25”/54cm
(2) 21.25”/54cm
2. Place the condensing unit through the counter cutout.
3. Extend the telescoping duct from the front of the
condensing unit to the back of the louver. This will
prevent recirculation of discharge air. Export models do
not have a telescoping duct, skip to step 6.
4. Put eight provided screws through the telescoping
duct side walls to hold it at the desired depth.
22.50”
(57cm)
C
E
D
A
B
18.50”
(47cm)
F
G
4.25”
(11cm)
Use Screws to Secure Desired Depth
3 of 8 Screws Shown
5. Partitions must fully extend front to back and top to
bottom.
6. Louver cutout must extend to bottom of cabinet and
align with condenser face.
NOTE: The louver provided must be installed in front of