background image

36 

DESIGNED SECURITY INC       

800-272-3555            www.dsigo.com  

1402 Hawthorne Street   Bastrop, Texas 78602         Fax 512 321 9181   

Email: [email protected]

 

INS8300 

 

When planning for an elevator lobby consider the maximum number of users that may need to be accommodated while 

waiting for the elevator.  Allow adequate space for the users to congregate beyond the turnstiles while not restricting traffic 

flow through the lane(s). 

 

 

 

The Ideal Application

 

 

The ideal placement will encourage users to approach slowly, enter, and pass through the lane, but discourage rushing 

through or stopping either in, or just after, the lane.  One example of ergonomics designed with this in mind would be a “T”-

type traffic pattern, with the entrance traffic flowing into the base of the “T”.   

 

If the ES8300 were placed in the corridor just before the “T”, users would not be prone to rush through the lane because they 

will see a wall or other barrier (rope, chain, etc.) before them.  After passing through the lane, there should also be some 

incentive to encourage moving on.   An inviting, open space like a lobby or waiting area or some place which is perceived as 

less confining than the security entryway would be ideal. 

 

Slowing traffic through the lanes minimizes false alarms generated through beam interruption by briefcases, bags, umbrellas, 

coats, etc. A rapidly moving user could be swinging these items and this has been known to generate a tailgate violation.   

 

Placing the turnstile in a long straight corridor may encourage this “swinging” of personal items by fast walkers or those 

users in a hurry, especially on free-exit applications.   

 

A free-exit user does not have to pause to present a card, he may be moving more rapidly.  A back-swing into the beams 

could be interpreted as an entry attempt by the electronics, thus producing a nuisance alarm. 

 

Naturally there will be a balance to be reached, in that the security entryway must also allow smooth traffic flow during peak 

traffic periods each day while still serving the purpose of limiting access to valid users of the system. 

 

With this knowledge of turnstiles, traffic flow and turnstile operational parameters in mind, a little planning beforehand could 

prevent conflicts later between users, operators, the integrator, and the customer’s original security plan. 

 

Moving the users through a psychologically “restrictive” area into an “inviting” open space, while also providing a security 

threshold large enough to allow smooth traffic flow during peak periods, would exemplify the ideal installation. 

Summary of Contents for DSI ES8300

Page 1: ...ES8300 ACRYLIC BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION INSTRUCTIONS...

Page 2: ......

Page 3: ...3 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 CUSTOM NOTES...

Page 4: ......

Page 5: ...5 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 SITE PREPARATION...

Page 6: ......

Page 7: ...straight forward installation when a little time is taken to prepare before you begin You may choose to take the time now to read and understand the installation and operation instructions in order t...

Page 8: ......

Page 9: ...9 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 INSTALLATION...

Page 10: ......

Page 11: ...be taken in placing the bollards to ensure that the user may easily access the Reader System I E Mag Card Proximity Biometric etc provided by installer integrator while maintaining a reasonable flow...

Page 12: ...ds is shown to help installers understand the proper placement of the Turnstiles in reference to the direction of traffic When entering the lane from the Secure side or Exit Side the Electronics Packa...

Page 13: ...ng finish or creating a hazard to pedestrian traffic PANEL INSTALLATION STEPS Place panel on Hinge Points Tilt into place in Bollard Insert T Handle Hex key wrench into small hole near the top side ed...

Page 14: ...can calculate the length of the long side C of any right angle triangle based upon the known length of the other two sides Use this device to verify alignment by referencing a chalk line on the floor...

Page 15: ...N ENCODER BARRIER PANEL D SENSORS C SENSORS B A SENSORS MOTOR ELECTRONICS PACKAGE MOUNTING POINTS CABLE ACCESS MOUNTING POINTS CABLE ACCESS END VIEW B SIDE SHOWN The A Side of each Bollard will have e...

Page 16: ...C Output Default Jumper covers upper and center pins for N O Output SET TRIMMERS setting of 10 1 second To reach top menu press M key 3 times Use down arrow to highlight 3 Trimmers Press Return Displ...

Page 17: ...ve to allow a user to exit from the secure side although the barriers may always be pushed open in an emergency The D1 2 3 Sensors work similarly for users exiting from the secure side IE blocking thi...

Page 18: ...el Below the Encoder is the Barrier Panel Located on the same shaft Units with optional Locking will have Locking Solenoid hardware mounted on this shaft This shaft goes into a shaft Coupler that allo...

Page 19: ...WIRING...

Page 20: ...lard when facing from the Entrance un secure side This bollard should have the Electronics Package in the side facing into the lane Leave adequate service loop in cables Route cables neatly in pedesta...

Page 21: ...op Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 ENCODER 2 CONNECTOR DETAIL MOTOR 2 CONNECTOR DETAIL PIN COLOR 1 Shield 2 Black 3 Vacant 4 Red 5 White 6 Green PIN COLOR 1 White 2 Black 3 Sh...

Page 22: ...sure which stows barriers N O Free Exit 15 16 Dry contact closure enables the Free Exit function N O Emergency 17 18 Dry contact closure moves Barriers to Exit activates alarm graphics and alarm relay...

Page 23: ...p over long cable run from Power Supply may create a high current condition that trips the breaker Use appropriate gauge wire for your installation LIGHT ARRAY CONNECTIONS Entry local and Exit adjacen...

Page 24: ......

Page 25: ...SETUP OPERATION...

Page 26: ......

Page 27: ...e the one you are aiming for Primarily on A and B Sensors Adjust Sensor bracket for a good signal lock LED Off indicates the Sensor is in alignment with the Reflector and in a stable operating state L...

Page 28: ...OR O O EXIT CARD O OR O O INVALID CARD O O O RESET BYPASS O O ENTRY CLOSED O EXIT CLOSED O ARM DISABLE O FREE EXIT EXIT WHEN D SENSOR IS BROKEN BY USER EMERGENCY O O VOICE ENABLE HORN DISABLE SILENT...

Page 29: ...AY SOUND MOVE THROUGH THE LANE PROMPTLY Avoid stopping or moving backward as this will trigger the alarm TIP During passage through the lane swinging items purses briefcases etc could be interpreted b...

Page 30: ...THEY SHOULD VISIT THE GUARD NOTE The single most frequent violation and cause of abuse results from Users pushing through the barriers It is important that the User be trained to NEVER touch the barr...

Page 31: ...31 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 APPENDIX...

Page 32: ......

Page 33: ...may optionally be N C see Page 16 N O Dry Contact for Alarm N O Dry Contact for Time Out N O Dry Contact for Valid Passage N O Dry Contact for Bypass N O Dry Contact for Invalid Card Accessory Power 1...

Page 34: ...e in feet of actual Wire Run from power supply to the most remote load 125 Multiply figures from above two lines Match final number to Table below to determine Wire Gauge needed to provide adequate Vo...

Page 35: ...ouble calls Pull Doors It is a good idea not to place the bollards immediately before a pull door The action of pulling the door open may cause the user to back into the lane This could generate a nui...

Page 36: ...ay would be ideal Slowing traffic through the lanes minimizes false alarms generated through beam interruption by briefcases bags umbrellas coats etc A rapidly moving user could be swinging these item...

Page 37: ...Automotive clear coat polishes work well for this application Turtle Wax s Clear Coat Polish and Restorer is what we use at the factory Powder Coat Painted Clean with mild soap water and a soft non ab...

Page 38: ...a larger gauge smaller number or increase the Supply Voltage in order to deliver 24 VDC at the Power Input Connector while the ES8300 is operating under load Symptom Numerous False Alarms These Alarms...

Page 39: ...nstalled used and maintained according to instructions DSI will for a period of three 3 years from date of purchase repair or replace any part which upon our examination proves to be defective under n...