28
DESIGNED SECURITY INC
800-272-3555 www.dsigo.com
1402 Hawthorne Street Bastrop, Texas 78602 Fax 512 321 9181
Email: [email protected]
INS8300
FINAL TESTING PROCEDURE
Provide Input or State from Left Column, Look for responses marked with
O
INPUTS
OUTPUTS
BARRIER
POSITION
ALARM TIMEOUT
VALID
PASSAGE BYPASS
INVALID
CARD AUDIBLE ENTRY EXIT CLOSED
ENTRY CARD
O
OR
O
O
EXIT CARD
O
OR
O
O
INVALID CARD
O
O
O
RESET/BYPASS
O
O
ENTRY CLOSED
O
EXIT CLOSED
O
ARM DISABLE
O
FREE EXIT
EXIT WHEN “D” SENSOR
IS BROKEN BY USER
EMERGENCY
O
O
VOICE ENABLE/HORN
DISABLE
SILENT WHEN IN ALARM
BARRIER AND SENSOR STATES
FORCED
ARM
& PASSAGE
O
O
BARRIERS WILL
PROVIDE RESISTANCE
AGAINST ATTEMPTS TO
FORCE PASSAGE
NO
PASSAGE
TAILGATE
O
O
WARNING:
Multiple lanes sharing a common Input Source must be isolated through a unique relay contact
for each lane input. Wiring common inputs in a daisy-chain (parallel) can cause damage to electronics.