![Delabie TEMPOFLUX 1 761627 Manual Download Page 10](http://html.mh-extra.com/html/delabie/tempoflux-1-761627/tempoflux-1-761627_manual_2465739010.webp)
INSTALLATION
THE INSTALLER MUST ENSURE:
•
THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS
OF WATER;
•
ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION,
RUN OFF, LEAKS, ETC.) HAS AN EXTERNAL DRAINAGE POINT TO PREVENT ANY STAGNATION;
•
THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER/TAP/VALVE AT LEAST ONCE A YEAR, AND MAKE GOOD
IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
EN
REMEMBER
•
Our valves must be installed by professional installers
in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
•
Sizing the pipes correctly
will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
•
Protect the installation
with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar maximum).
•
Install stopcocks
close to the valve to facilitate maintenance.
•
The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.
MAINTENANCE & CLEANING
•
Cleaning chrome, aluminium and stainless steel:
do not use abrasive, chlorine or any other acid-
based cleaning products. Clean with mild soapy water using a cloth or a sponge.
•
Frost protection:
drain the pipes and operate the valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing
them indoors.
After Sales Care Support:
For the UK market only:
Tel.
01491 821 821 -
email:
The installation guide is available on: www.delabie.co.uk
For all other markets: Tel.
+33 (0)3 22 60 22 74 -
email:
The installation guide is available on: www.delabie.com
MAINTENANCE
Water discharge from the vacuum breaker:
Check flush tube is not fully inserted up to the WC pan and check flush tube radius is at 50mm.
No flush:
Dynamic pressure is too weak, pipework sizing is incorrect, or flush tube curve is 90°.
BEWARE: DO NOT grease the inside of the mechanism.
Summary of Contents for TEMPOFLUX 1 761627
Page 3: ...R50 min 500 min 400 min Ø32 B D A C E 0 ...
Page 4: ...F H J1 G I J2 Réf 761 Ø38 Réf 762 M42 7 sec x3 PUSH ...
Page 5: ...J3 K1 L1 J4 K2 L2 K3 L3 761627 761900 ...
Page 6: ...M1 N1 M2 N2 762902 ...
Page 7: ...AA AC AE AB AD AF 761627 761900 10 sec TURN MAX 7 mm ...
Page 8: ...AG AI AH AJ 762902 10 sec ...