Total Eclipse
Installation & Operations Manual
4
main circulation pump, the red light will go out, indicating that
the unit is operating properly.
2C. Maintenance - Refer to Figure 5
2C‐1. Ozone Module Replacement
The Ozone Module consists of a power supply and ozone cell.
The Ozone modules have a life expectancy of 15,000 hours
(approximately two years for continuous use and five years for
seasonal use).
1. Turn off electrical power and unplug Total Eclipse.
2. Remove the ozone generator from its support if access is
limited.
3. Remove Total Eclipse cover by removing the (3) Phillips head
screws that attach cover to generator base.
4. Remove (1) Phillips head screw that holds Ozone Power Supply
to the Module Mounting plate.
5. Remove Air Filter by pulling filter away from Ozone Cell then
pull ozone cell out of oz module manifold.
6. Disconnect the Ozone Power Supply by pulling the Wire
Connector apart from the wire harness.
7. Reverse process to install new Ozone Module.
2C‐2. Check Valve Replacement
The ozone check valve should be replaced annually to avoid back
flooding issues.
1. To replace Ozone Check Valve remove the two black hose
clamps and pull the tubing away from the check valve.
2. Reverse the process to install new check valve being careful
to note flow direction of Check Valve (arrow points toward the
injector).
2C‐3. Air Filter Replacement
The air filter should be replaced when replacing the ozone modules
or sooner if necessary in dusty environments.
1. To replace air filter pull filter away from ozone cell.
2. Reverse process to install new filter.
2C 4. Winterizing the Total Eclipse
To winterize the Total Eclipse, unscrew the unions connecting it to
the inlet and outlet plumbing. The water will drain out of the Total
Eclipse and make it ready for winter. Once the water has drained,
tighten the unions. When restarting your pool and/or spa equipment,
the Total Eclipse will restart itself once water starts flowing through it.