99
Total Eclipse
Installation & Operations Manual
4. The Total Eclipse lost power during a power outage.
Once power returns to the main pool pump and the Total
Eclipse, it will restart and continue running as soon as flow is
detected from the main pool pump.
5. The Total Eclipse continues to run when the main filtration
system is turned off.
The Total Eclipse is designed to run independent of the main
filtration system. When the main pump to the filter system
shuts down, the Total Eclipse will continue to run, continuously
ozonating the pool water.
6. Bubbles appear in the pool when the unit is running.
Some fine bubbles into the pool are normal. To avoid any
large bubbles being trapped and released, plumb with a single
3/4” line independently returned to the bottom of the pool. In
addition, keep all pipe runs to the pool straight and level using a
minimum number of elbows and fittings.
NOTE: The collection of air bubbles in the system can be
minimized by installing a DEL MDV-20.
SECTION 4
4A. Ordering Information
To locate a dealer nearest you visit www.delozone.com or call DEL
at 1-805-541-1601 ext 249.
Be prepared with the following information:
• Name
• Address
• DEL Model #
• Date Purchased
4B. Standard Replacement Parts List
1. Ozone Module Sub‐Assemblies: *
a. ECT-2 Models ...........................9-1094-01
b. ECT-4 Models ...........................9-1094-02
2. Ozone Module ...............................9-1056-01
3. Ozone Check Valve .......................7-1140-01
4. Air Filter .........................................9-0858-01
5. Tubing,Green,PVC ........................7-0594
*Pre‐assembled Includes: Ozone Modules, Mounting Plate,
Manifold with fittings, Air Filters and Relay.*