2

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS.

• 

Read this manual completely before attempting installation.

• 

All permanent electrical connections should be made by a qualified 
electrician.

• 

For cord and plug-connected units, connect to a grounded, grounding 
type receptacle only. If the Total Eclipse™ electrical connection is to be 
attached to the pool controls, be sure the pool controls are protected 
by a Ground Fault Circuit Interrupter (G.F.C.I.). If the Total Eclipse™ is 
connected to an independent electrical supply, then a G.F.C.I. must be 
installed between the Total Eclipse™ and the electrical supply.

• 

Do not bury cord.

• 

Warning - To reduce the risk of electrical shock, replace damaged cord 
immediately.

• 

A pressure wire connector is provided on the outside of the unit to permit 
connection to a minimum No. 8 AWG (8.4 mm2) solid bonding conductor 
between this point and any grounded metal equipment, grounded 
metal enclosures of electrical equipment, metal water pipes, or conduit 
within five (5) feet (1.5m) of the unit as needed to comply with local 
requirements.

• 

Install at least 5 feet (1.5 meters) from wall of pool water using 
nonmetallic tubing. It is highly recommended that the ozone generator 
be installed at least one (1) foot above the water level to prevent water 
from contacting electrical equipment. Install in accordance with the 
installation instructions.

• 

Follow all applicable electrical codes.

• 

Electric shock hazard. Be sure to turn power OFF and disconnect from 
power source before any service work is performed. Failure to do so 
could result in serious injury or death.

• 

The Total Eclipse™ must be installed in an outdoor location, or indoors 
in a forced air ventilated room, and installed so that the orientation 
is exactly as shown in Figure 1. Install to provide water drainage of 
generator to protect electrical components.

• 

Mount the Total Eclipse™ so that it is inaccessible to anyone in the pool. 
Never attempt any servicing if the unit is wet.

• 

Plastic ozone supply tubing is inside the Total Eclipse™. Never replace 
this tubing with metal tubing.

• 

Warning - Short-term inhalation of high concentrations of ozone and 
long term inhalation of low concentrations of ozone can cause serious 
harmful physiological effects. DO NOT inhale ozone gas produced by 
this device.

• 

For your safety, do not store or use gasoline, chemicals or other 
flammable liquids or vapors near this or any other appliance.

SAVE THESE INSTRUCTIONS!

Summary of Contents for Total Eclipse Series

Page 1: ...4 0026 Rev F ECT 2 and ECT 4 Installation Operations Manual Total Eclipse...

Page 2: ...of pool water using nonmetallic tubing It is highly recommended that the ozone generator be installed at least one 1 foot above the water level to prevent water from contacting electrical equipment I...

Page 3: ...pecifications 1 SECTION 2 Installation Operation 2A Installation 1 2B Operation 3 2C Maintenance 4 SECTION 3 Trouble Shooting 8 SECTION 4 Replacement Parts Ordering Information 4A Ordering Information...

Page 4: ...w switch and check valve for protection of pump and ozone modules SECTION 2 Installation Operation 2A Installation The most common pool and pool spa configurations are discussed in this manual For add...

Page 5: ...s highly recommended Bubble formation and gurgling may occur otherwise NOTE Air bubbles in the system can be removed by installing a DEL MDV 20 Contact your local dealer or visit DEL s website at www...

Page 6: ...ssary If no winterizing will take place unions are still included to facilitate unit removal if necessary 2B Operation Once the Total Eclipse has been properly installed simply plug the unit into a 12...

Page 7: ...ng the Wire Connector apart from the wire harness 7 Reverse process to install new Ozone Module 2C 2 Check Valve Replacement The ozone check valve should be replaced annually to avoid back flooding is...

Page 8: ...for Infloor Cleaning System 2 Even when the ICS is not operating bubbles from the ozone generator will escape through the ICS head 5 Total Eclipse Installation Operations Manual Common Installation D...

Page 9: ...t using an eyeball fitting or reducer nozzle at the point of entry ie the wall This will help to break up the bubbles and push them further out preventing any possible discoloration to the pool wall N...

Page 10: ...nits Ozone Check Valve Ozone Injector Expansion Fitting Water In Water Out Power Indicator Light No Flow Indicator Light Air Filter cap and cotton filter one per ozone module Ozone Module Manifold bla...

Page 11: ...a new sanitation device like the Total Eclipse will destroy a great deal of contaminants in the water and leave them to be filtered out Therefore you many find it necessary to clean your filter to un...

Page 12: ...d any large bubbles being trapped and released plumb with a single 3 4 line independently returned to the bottom of the pool In addition keep all pipe runs to the pool straight and level using a minim...

Page 13: ...10 APPENDIX A Warranty APPENDIX A Warranty...

Page 14: ...egligence accident fire flood repair materials and or unauthorized accessories c Any such products installed without regard to required local codes and accepted trade practices d Damage to unit caused...

Page 15: ......

Page 16: ...3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001...

Reviews: