Product-Notes Manual
Article No.: 843053
Deko-Light Elektronik-Vertriebs GmbH
29.03.2021
www.deko-light.com / [email protected]
Technical Data can be changed without advance notice. Errors excepted.
6 / 22
II. Commissioning and connection of the controller
The following sketches show the connection and the wiring of the controller as well as the different modes.
1.
Connection PWM-easy - 1 Channel Mode / Single
NOTE!
Important information about the max. Switching
capacity:
LED lights / LED strips with max. 8.0 A
Total power (12V / 96W, 24V / 192W, 48V / 384W)
only in bridged mode!
Please note urgently that overloading the individual
channels will destroy the controller! The specified
max. Under no circumstances may loads be
exceeded.
For the max. Load in bridged mode, the
corresponding 1-channel mode (delivery
status) must be selected and all 4 output
channels must be electrically connected by
cable bridges!
optional connection of up to 4 buttons
for the operation of permanently stored
switching tasks or scenes
see push button connection diagram (page 10)
Any kind of voltage constant (CV) LED lights / stripes etc. with suitable voltage /
power and common anode (+) can be connected. (max. 5 pieces of the same type)