DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-E02 / September 2019
24
RESETTING MAINTENANCE SCHEDULE HOURS
Enter Password
When maintenance is due you will see a warning on the screen letting you know that maintenance is due on the
system. To remove this warning you must reset the maintenance interval. Press the MAINT button until you see
the maintenance interval screen. The 0 shows the period has expired and generates the warning on the screen.
You must reset the HRS To Srv to 500 or the schedule selected. Use DOWN key to select HRS TO SRV and
press ENTER. Use UP key to reset to the correct interval (500 in this case). Press ENTER again to save, this last
press of ENTER also records the date and time this service was completed in the Service History log.. Pressing
ESC will take you back to the main screen and the warning will be gone. Note: warnings and faults only show in
run mode.