1.2
Attaching the ceiling adapter to a concrete ceiling
Use the assembled bracket and column as a template to mark the positions of the three bracket securing holes on the
ceiling.
Drill the holes Ø 10mm (3/8’’) and 30mm (13/16’’) deep. Insert the MK8 expansion screws in each hole and tighten
them in place.
Screw the levelling nuts on to the expansion screws.
Fastening
holes