4, rue de Jarente - F 75004 Paris
Tel: +33 (0)1 71 18 18 60
Fax : +33 (0)9 70 80 10 00
S A S a u c a p i t a l d e 1 0 5 0 0 0
€
R C S P a r i s B 4 0 2 2 1 1 0 1 5
T V A : F R 0 5 4 0 2 2 1 1 0 1 5
28/29
2. Adjusting position of all opteleds
Optimize the light shape and sharing out of the LOLe light through an adjustment of opteleds’ light
superposition: the LOLe light consists in a superposition of all 4 opteleds’ light.
1- Connect the light to the mains supply and switch the
light on.
Direct the light towards a plane surface 70cm far.
The light fields from all 4 opteleds must be on the
same level.
If they are not, the vertical position can be adjusted.
Light field misaligned
2- Loosen the attachment screws using a 2.5mm Allen
key and move the opteled to the correct position.
3- Tighten the attachment screws and re-check the
light field.
4- Switch the light off and attach both front cover and
protective fascia.