Connecting energy converter to Central Control Box
Assembly Instruction DEGER
traker
3000NT / 3000HD / 5000NT / 5000HD / 6000NT / 7000NT / 9000NT
2012-07-01
Page V-5
Open the housing cover on the Central Control Box and energy converter, then connect the two devices to
each other as follows:
Connecting the energy converter 6 to the Central Control Box II:
with wind guard BASIC
1
16
16
2
17
17
3
18
18
4
19
19
CCBII
EK 6
next EK 6
Control cable for remote control
Connecting the energy converter 6 to the Central Control Box III
with wind guard ADVANCED/STANDARD
Optional connection for SAFE POS
-
20
20
23
21
21
32
31
22
30
+
1
-
1
16
16
2
+
2
17
17
5
+
3
18
18
4
35
4
19
19
Anemometer
Evaluation unit
CCBIII
EK 6
next EK 6
wind guard
wind guard
Control cable for remote control
The conductor cross-section of the control cable has to be appropriate for the number of energy
converters connected to the Central Control Box and the cable length.
The cable for connecting to
EK 6 to CCB is not included. To connect the remote control a 4-wire cable is enough, to connect the
optional SAFE POS, a 6-wire cable is required.
The power supply (100 - 240 V) for the energy converter (PE - L - N) and Central Control Box (A-B Uin) must
be provided by a qualified technician externally on-site.
ATTENTION!
Connection of the energy converter to the Central Control Box may only be carried out by
specialist personnel and only when disconnected from the power supply.
ATTENTION!
The external power supply must be set up according to the local regulations.
It must be possible for the energy converter to be cut off from the supply voltage by means of a
safety cut-out switch 10A B or 6A C. It must also be possible for the Control Box to be cut off from
the supply voltage by means of a safety cut-out switch 3A B.
The safety cut-out switch must be readily accessible.