Assembly Instruction
DEGERtraker
Part IV
– Module carry system
DEGERtraker 6000NT
Assembly Instruction DEGER
traker
3000NT / 3000HD / 5000NT / 5000HD / 6000NT / 7000NT / 9000NT
2012-07-01
Page IV-3
Module arrangement:
The following dimensions have to be abode and have to be reduced according to regional conditions if
necessary:
- Module surface:
max. 53m²
- length of Module surface:
max. 10.05m
- height of Module surface:
max. 5.60m
The total module area is to be determined relative to the site with the aid of the DEGERenergie
dimensioning tool and may in no case be greater than 53m².
1st step: Arrangement of aluminium profiles:
Distance between 2 aluminium profiles:
x
= width of module / 2
(
attend the point of fastening from the modul manufacturer
)
Overhang of the aluminium profile
:
y
= (length of aluminium profile - 2.60m) / 2
Following points have to be attended:
- assemble aluminium profile from the middle to the outsite
- in both axis modules have to be arranged symmetrically to the center of gravity
- 2 aluminium profiles for each row of modules
- attend the connecting socket on the backside of the modules
2nd step: Assembly of aluminium profiles
see Page IV-6!
In the range of the suspension
for the elevation motor it is not
possible to assemble the MTH-
clamps at the outside of the base
frame. Here the MTH-clamps
have to be assembled at the
inside of the base frame.
Please pay attention to notes in
step 2!