- As a person moves through the building, each fitting detects motion and continues to signal the
others to stay on.
- The Hold Period and subsequent Standby Period (see Sensor Manual) does not start running
until no more activation signals are received.
- The Hold and Standby Periods start running at the same time for all connected fittings.
This means that they also turn off at the same time.
100%
100%
100%
- Since all connected LedgeCircle
®
RF fittings detect motion forward activation signals to each other,
the installation behaves in the same way no matter which fitting first detects motion.
100%
100%
100%
Hold
Period
10%
10%
10%
Standby
Period
Off
Off
Off
Off
- The Hold Period starts when after the last detection/activation signal has been received. The light
remains at the Max level during this period. Once the Hold Period expires the light goes down to the
to the selected Min level for the Standby Period.
- Detection range, Hold and Standby Period duration and Standby dimming level can be configured
with the remote.