Radar activation - example 2:

Grouped responses. Connected fittings respond either by turning ON to the Max level or by turning ON to the 

selected Standby/Min level. MinMaxOff mode.

-  All fittings in the installation are OFF by default.

-  The first connected fitting to detect motion sends  

  an activation signal and turns on to the Max level.

-  Fittings on the same floor respond to the 

  activation signal in the same way.

-  The first fitting on the floors above and below    

  respond by turning ON to the selected Standby/  

  Min level, and the Standby Period starts running.

Off

Off

Off

Off

100%

100%

100%

100%

10%

Off

Off

Off

100%

100%

100%

100%

2

-  A person moving to the second floor is detected  

  by the first fitting, already at the Standby Min level.

-  The fitting goes from the selected Min level to    

  100% and sends an activation signal. 

-  Fittings on the second floor respond by also 

  turning ON to the Max level.

-  The stairwell fitting in the third floor responds by  

  turning ON to the selected Standby level. 

-  The fittings in the first floor remain at the Max level  

  for the duration of the Hold Period. 

-  Note that when the fittings in the first floor are not 

  already on (e.g. the person is leaving from the

  second floor), the stairwell fitting on the first floor  

  will also respond by turning ON to the selected   

  Min level.

RF Radar | MinMaxOff

Summary of Contents for LedgeCircle RF

Page 1: ...1 www defa com 122577 EN Rev E04 0920 LedgeCircle RF Manual NB Please find the manual in other languages on www defa com or scan the QR code Norsk Svensk...

Page 2: ...ost likely to occur at the top floors of buildings with or near such antennas How it works Each LedgeCircle RF fitting can receive activation signals from up to 30 other fittings and be set to respond...

Page 3: ...e time 100 100 100 Since all connected LedgeCircle RF fittings detect motion forward activation signals to each other the installation behaves in the same way no matter which fitting first detects mot...

Page 4: ...level and the Standby Period starts running Off Off Off Off 100 100 100 100 10 Off Off Off 100 100 100 100 2 A person moving to the second floor is detected by the first fitting already at the Standby...

Page 5: ...period duration and Standby dimming level can be configured with the remote RF Radar MinMaxOff 10 10 10 10 100 100 100 100 100 100 100 100 10 Off Off Off 3 As the person continues to move up the stair...

Page 6: ...ct another fitting Fitting 2 and take it out of Learn mode by pointing the remote to it and pressing the Learn Erase button Point the remote to Fitting 2 again and press Transmit As before all fitting...

Page 7: ...fault settings Shift This feature is not available with LedgeCircle RF fittings Power output Press Power 80 to reduce power input to 80 This can be done during the first year or the first 10 000 hours...

Page 8: ...ime to 30s 5min 15min 30min press the Shift button first Standby dimming level Set the Standby dimming Min level to 10 20 30 50 Remote Control RF Wireless Dual Tech RF mode Use the Learn Erase and Tra...

Reviews: