How to set up your installation

To set up your LedgeCircle

®

 RF installation, first consider where fittings will be installed, which fittings that 

should obey each other and how you want each fitting to respond to an activation signal. You should also 

consider what durations the Hold and Standby periods should have, what you want the Standby dimming/

Min light level to be and whether you should adjust the Sensor Sensitivity in certain fittings to prevent them 

from being triggered by motion behind doors or windows.

Connection

 

-  Set one fitting aside. This will be the first fitting that the others learn to obey (Fitting 1).

 

-  In turn, point the remote to each of the other fittings and press and hold the “Learn/Erase” 

 

  button on the remote.

 

-  When the fittings enter Learn-mode, they will start to beep once per second. 

 

-  Repeat this for all fittings you want to receive activation signals from Fitting 1.

 

-  Each fitting will remain in learn mode for 3 minutes, unless manually cancelled.

 

-  Now, point the remote to the Fitting 1 and press “Transmit”.

 

-  The fittings in Learn-mode will confirm that the pairing has been established by beeping rapidly 

 

  3 times. They will now all respond to activation signals from Fitting 1.

 

-  To interconnect all fittings, now point the remote to Fitting 1 and press and hold the “Learn/Erase”  

 

  button until it enters Learn-mode.

 

-  Place fittings that have completed the "Transmit" to one side, apart from those who have not.

 

-  Now select another fitting (Fitting 2) and take it out of Learn-mode by pointing the remote to it and  

 

  pressing the “Learn/Erase” button.

 

-  Point the remote to Fitting 2 again and press “Transmit”.

 

-  As before, all fittings in learn mode will beep rapidly 3 times to confirm that the pairing is successful.

 

-  Repeat above steps until all fittings have learnt to respond to activation signals from all other fittings.

Selecting responses

 

-  Responses are selected with the RX 100% and RX STBY% buttons on the remote.

 

-  By selecting RX STBY% the fitting will go to your selected Standby dimming/Min level when activated.

 

-  This also means that the fitting will go straight to the Standby Period. Once your selected Standby  

 

  Period duration expires, the fitting will turn OFF.

 

-  Point the remote to each fitting and press the button corresponding with your preferred response.

 

-  The factory setting for LedgeCircle® RF fittings is RX STBY%.

Mounting

 

-  NOTE! Please read the sensor and configuration instructions before mounting.

 

-  Be aware that each fitting as a maximum indoor communication range of 30 meters. 

 

-  For instructions, see the separate mounting manual provided with each fitting.

RF Radar | MinMaxOff

Using the Remote Control, follow the procedure described below:

The Rotary Switch

  is located inside 

   the fitting

RF grouping via Rotary Switch

By selecting the same channel on the Rotary switch for all fittings in a 

preferred group the grouping is automatically completed. 

Use a screwdriver to point the arrow to the selected channel.

Connect fittings, select responses

To make the setup and connection procedure as efficient as possible, place the fittings you wish to connect 

in front of you.

Summary of Contents for LedgeCircle RF

Page 1: ...1 www defa com 122577 EN Rev E04 0920 LedgeCircle RF Manual NB Please find the manual in other languages on www defa com or scan the QR code Norsk Svensk...

Page 2: ...ost likely to occur at the top floors of buildings with or near such antennas How it works Each LedgeCircle RF fitting can receive activation signals from up to 30 other fittings and be set to respond...

Page 3: ...e time 100 100 100 Since all connected LedgeCircle RF fittings detect motion forward activation signals to each other the installation behaves in the same way no matter which fitting first detects mot...

Page 4: ...level and the Standby Period starts running Off Off Off Off 100 100 100 100 10 Off Off Off 100 100 100 100 2 A person moving to the second floor is detected by the first fitting already at the Standby...

Page 5: ...period duration and Standby dimming level can be configured with the remote RF Radar MinMaxOff 10 10 10 10 100 100 100 100 100 100 100 100 10 Off Off Off 3 As the person continues to move up the stair...

Page 6: ...ct another fitting Fitting 2 and take it out of Learn mode by pointing the remote to it and pressing the Learn Erase button Point the remote to Fitting 2 again and press Transmit As before all fitting...

Page 7: ...fault settings Shift This feature is not available with LedgeCircle RF fittings Power output Press Power 80 to reduce power input to 80 This can be done during the first year or the first 10 000 hours...

Page 8: ...ime to 30s 5min 15min 30min press the Shift button first Standby dimming level Set the Standby dimming Min level to 10 20 30 50 Remote Control RF Wireless Dual Tech RF mode Use the Learn Erase and Tra...

Reviews: