How to set up your installation
To set up your LedgeCircle
®
RF installation, first consider where fittings will be installed, which fittings that
should obey each other and how you want each fitting to respond to an activation signal. You should also
consider what durations the Hold and Standby periods should have, what you want the Standby dimming/
Min light level to be and whether you should adjust the Sensor Sensitivity in certain fittings to prevent them
from being triggered by motion behind doors or windows.
Connection
- Set one fitting aside. This will be the first fitting that the others learn to obey (Fitting 1).
- In turn, point the remote to each of the other fittings and press and hold the “Learn/Erase”
button on the remote.
- When the fittings enter Learn-mode, they will start to beep once per second.
- Repeat this for all fittings you want to receive activation signals from Fitting 1.
- Each fitting will remain in learn mode for 3 minutes, unless manually cancelled.
- Now, point the remote to the Fitting 1 and press “Transmit”.
- The fittings in Learn-mode will confirm that the pairing has been established by beeping rapidly
3 times. They will now all respond to activation signals from Fitting 1.
- To interconnect all fittings, now point the remote to Fitting 1 and press and hold the “Learn/Erase”
button until it enters Learn-mode.
- Place fittings that have completed the "Transmit" to one side, apart from those who have not.
- Now select another fitting (Fitting 2) and take it out of Learn-mode by pointing the remote to it and
pressing the “Learn/Erase” button.
- Point the remote to Fitting 2 again and press “Transmit”.
- As before, all fittings in learn mode will beep rapidly 3 times to confirm that the pairing is successful.
- Repeat above steps until all fittings have learnt to respond to activation signals from all other fittings.
Selecting responses
- Responses are selected with the RX 100% and RX STBY% buttons on the remote.
- By selecting RX STBY% the fitting will go to your selected Standby dimming/Min level when activated.
- This also means that the fitting will go straight to the Standby Period. Once your selected Standby
Period duration expires, the fitting will turn OFF.
- Point the remote to each fitting and press the button corresponding with your preferred response.
- The factory setting for LedgeCircle® RF fittings is RX STBY%.
Mounting
- NOTE! Please read the sensor and configuration instructions before mounting.
- Be aware that each fitting as a maximum indoor communication range of 30 meters.
- For instructions, see the separate mounting manual provided with each fitting.
RF Radar | MinMaxOff
Using the Remote Control, follow the procedure described below:
The Rotary Switch
is located inside
the fitting
RF grouping via Rotary Switch
By selecting the same channel on the Rotary switch for all fittings in a
preferred group the grouping is automatically completed.
Use a screwdriver to point the arrow to the selected channel.
Connect fittings, select responses
To make the setup and connection procedure as efficient as possible, place the fittings you wish to connect
in front of you.