TLC-360 

 

4 ELEMENT 

CEILING MOUNT 

PASSIVE INFRARED DETECTOR 

 
 
             

 

 

 

 

INSTALLATION INSTRUCTIONS 

P/N 7151069 

REV.E   A.Y.

 

 

 

TLC-360 FEATURES  

  Fully sealed sensor chamber. 

  VLSI Technology (Very Large Scale 

Integration). 

  Maximum RFI & EMI Immunity. 

  4 Element Pyro Sensor. 

  Pulse Count. 

  Sophisticated signal processing. 

  Memory function. 

  Hard Spherical Lens 360

°

 coverage. 

  Bidirectional temperature compensation. 

  Flourescent light stability. 

  

INTRODUCTION 

The TLC-360 is a 4-element passive infrared 
intrusion detector for use in electronic 
security systems in ceiling mount 
applications. 

You will obtain optimum performance from 
your TLC-360 PIR detector by following this 
manual. 

 

 

The TLC-360 reduces false alarms to an 
unprecedented minimal level due to its 
effective elimination of background noises and 
nuisance stimuli. The TLC-360 employs 
Automatic Pulse Count making it extremely 
adaptable to various environments. The 
unique VLSI, using sophisticated signal 
processing, makes this detector virtually free 
of false alarms. 

The TLC-360 integrates VLSI & SMD 
(surface mount device) to their full advantage. 

The detector is easy to install, with no 
necessary adjustments. 

HARD SPHERICAL LENS 

The TLC-360 is equipped with a special hard 
lens. This lens is the latest development in the 
security field and complies with all the new 
standards requirements. It gives wide 
coverage patterns, even at low mounting 
heights. It is especially immune to sunlight, 
halogen lights and fluorescent lights and is 
impervious to attack. 

 

 

 

MOUNTING THE DETECTOR 

Choose location most likely to intercept an 
intruder. Refer to the detection pattern. 

1.  Hold the detector in your hand and 

release the mounting plate by turning it 
counter-clock-wise, and separate it 
from the case (Fig. 1). 

2.  Insert the wires through the hole in the 

center of the mounting plate (Fig. 2). 

3.  Mount the plate using the holes marked 

mounting holes. 

WIRE SIZE REQUIREMENTS 

Use #22 AWG (0.5 mm) or wires with a 
larger diameter. Use the following table to 
determine required wire gauge (diameter) 
and length of wire between the detector and 
the control panel. 
Wire Length        m  200   300    400    800 
Wire Diameter   mm  .5     .75     1.0     1.5 
Wire Length        ft. 800  1200  2000  3400 
Wire Gauge        #    22     20      18      16 

 

FIG. 1 - TLC-360 . EXTERNAL VIEW 

 

 

 

 

FIG. 2 - TLC-360. INTERNAL VIEW 

 
 

 

 

 

 

TERMINAL BLOCK CONNECTIONS 

 
Run the cable through the cable entry hole 
and connect the wires in accordance with 
the following instructions:

 

Terminal 1 - Marked “ - ” ( GND ) 

Connect to ground of the control panel. 

Terminal 2 - Marked “ + ” ( + 12V ) 

Connect to a positive Voltage output of 8.2-
16 Vdc source (usually from the alarm 
control unit). 

Terminals 3 & 4 - Marked “ RELAY ”

 

These are the output relay contacts of the 
detector. Connect  to a normally closed zone 
in the control panel. 

Terminals 5 & 6 - Marked “ TAMPER ”  

If a Tamper function is required connect

 

 

these terminals to a 24 hour normally closed 
protective zone in the control unit. If the front 
cover of the detector is opened, an 
immediate alarm signal will be sent to the 
control unit. 

Terminal 7 - Marked “ MEM ”

 

End Of Line option 

 

PULSE COUNT /LED Enable

 DIP S

witch

 

(Fig.3 and DIP-SWITCH Setting).  
To change positions of the DIP-switch you 
have to open the detector: 

1.  Turn the detector counter-clock wise and 

separate it from the mounting base. 

2.  Change position of the switch. 
3.  Close the detector and reinstall assembly 

screws. 

 

 

Pulse Count / 
LED Enable Switch 

Sensitivity/Range 
Adjustment 

Rubber 
Insulation 

Terminal Strip 

OPEN

 

CLOSE

 

O

 

C

 

Separate cover 
from base 