Model
Unit
ETWH 180 E
ETWH 230 E
Sound power level, indoors (L
WA
)
dB
60
60
Storage volume (V)
Litre
180.0
230.0
Mixed water at 40°C (V40)
Litre
207
318
Heat input (HP)
W
1000
1000
Absorbed electrical power (HP)
W
/ 460
/ 460
COP in accordance with the EN16147 standard
2.38
2.51
Maximum air flow rate
m
3
h
350
350
Electrical resistor output
W
1550
1550
Operating pressure
MPa (bar) 0.8 (8)
0.8 (8)
Power supply voltage
V
230
230
Circuit breaker
A
16
16
Heating time (10-54°C)
hours
8h39
Pes
W
37.0
46.9
Refrigerant fluid R-134a
kg
0.8
0.8
tCO
2
e
1.14
1.14
Weight of the tank (empty)
kg
102
116
Protection of the thermodynamic water heater
IP21
IP21
Acoustic pressure
dB (A)
46.2
46.2
Minimum water inlet pressure
MPa (bar) 0.15 (1.5)
0.15 (1.5)
Maximum water inlet pressure
MPa (bar) 0.65 (6.5)
0.65 (6.5)
(1) Value obtained with an air temperature of 7°C when heating from 10°C to 54°C.
(2) Value obtained with an air temperature of 15°C when heating from 10°C to 54°C.
(3) Value obtained with an air temperature of 7°C and a water inlet temperature of 10°C according to EN16147 based on LCIE Specifica
tions No. 103-15/B: 2011.
(4) Value obtained with an air temperature of 15°C and a water inlet temperature of 10°C according to EN16147 based on LCIE Specifica
tions No. 103-15/B: 2011.
(5) Absorbed electrical power at stabilised rate.
(6) Quantity of refrigerant calculated in tonnes of CO
2
equivalent.
(7) Measured at a distance of 2 metres.
3 Technical specifications