9 Settings
9.1
List of parameters
The following parameters can be accessed in all operating modes:
ECONOMY MODE / HYBRID MODE / OPT.BACKUP
Tab.7
Parameters available in the operating modes
Parameter
Description
Factory setting
:
Water temperature difference between the set point and the
restart.
Can be set from 3 to 20°C.
5°C
:
Room temperature limit authorised for operation of the heat
pump.
5°C
:
Room temperature operating limit for the electrical back-up.
Can be set from 5 to 18°C
10°C
:
Main timer range duration at Off-peak rate if cabled
8 hours
9.2
Setting the parameters
9.2.1
Selecting the operating mode
1. Unlock the control panel by pressing the CANCEL key for 3 seconds.
The locking indicator goes out.
2. Select the required mode by pressing the MODE key.
3. Confirm the required operating mode by waiting 10 seconds.
9.2.2
Setting the various parameters
The adjustable parameters are as follows, regardless of the selected
operating mode
1. Access the setting parameters by pressing the two keys opposite
simultaneously.
2. Adjust the value for the parameter
by pressing the keys opposite.
3. Adjust the parameter
by pressing the keys opposite.
4. Adjust the parameter
by pressing the keys opposite.
9.2.3
Configuring the anti-legionella function
Switch off the power supply by pushing the circuit breaker down to the
OFF position.
Fig.23
MODE
MW
-5
0
0
0
4
9
2
-1
Fig.24
MW
-1
0
0
0
7
4
3
-1
Fig.25
MW
-1
0
0
0
7
4
3
-1
Fig.26
MW
-1
0
0
0
7
4
3
-1
9 Settings
42
ETWH
7629886 - v07 - 20072020