Performances related to the boiler type
Gas fired floor-standing condensing boiler
(1)
10/15 kW
15 kW
25 kW
35 kW
Power exchanged
kW
15
15
28
32
Flow per hour (∆T = 35°C)
(2)
l/h
370
370
690
790
Draw-off capacity
l/10 mm
200
200
240
245
Specific flow (∆T = 30°C)
(3)
l/min
20
20
24
24.5
Q
p
: Primary flow rate
m
3
/h
1.1
1.1
1.1
1.5
(1) Depending on the country in which the boiler is installed
(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C
(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Tank temperature: 60 °C
Performances related to the boiler type
Floor-standing condensing oil boiler
(1)
18 kW
24 kW
30 kW
Power exchanged
kW
18
24
30
Flow per hour (∆T = 35°C)
(2)
l/h
440
590
740
Specific flow (∆T = 30°C)
(3)
l/min
21
23.5
24
Draw-off capacity
(3)
l/10 mm
230
235
240
Q
p
: Primary flow rate
m
3
/h
1.0
1.0
1.1
(1) Depending on the country in which the boiler is installed
(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C
(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Tank temperature: 60 °C
3.2.2.
Specifications of the DHW sensor
Temperature in °C 10
20
25
30
40
50
60
70
80
Resistance in ohm 19691 12474 10000 8080 5372 3661 2536 1794 1290
3. Technical description
160 SL
9
15/03/2012 - 300026901-001-C