9.1.4
Blocking of the boiler
A (temporary) blocking mode is a boiler status, resulting from an abnormal
state.
The blocking code for the boiler is accessed via the parameter HM042 in
the Information menu.
Important
The boiler automatically returns to operation once the cause of the
blocking has been removed.
When one of the codes below is displayed, contact the professional
responsible for maintenance of the boiler.
Tab.40 Blocking codes
Blocking code
Description
0
Parameter error
1
Maximum flow temperature exceeded
2
Maximum increase of the flow temperature has been exceeded
7
Maximum difference between the flow and return temperature exceeded
10
Blocking input is active
11
Blocking input active or frost protection active
12
Communication error with the boiler PCB
13
Communication error with the PCB
14
Hydraulic pressure too low
15
Gas pressure too low
16
Configuration error
17
Configuration error or default parameter table incorrect
18
Configuration error or PSU PCB not recognised
19
Configuration error or parameters dF and dU unknown
20
Configuration procedure active
21
Communication error with the SU PCB
22
No flame during operation
25
Internal fault in the gas/air unit
(1) These lockouts are not stored in the error memory
9.1.5
Locking of the boiler
If the blocking conditions are still present after several start-up attempts,
the boiler becomes locked out (also called error mode). The boiler can
only start operating again once the causes of the lock-out have been
rectified and after pressing the
button.
The locking code can be accessed via the parameter HM041 in the
Information menu.
When one of the codes below is displayed, contact the professional
responsible for maintenance of the boiler.
Tab.41 Error table with error codes
Error code
Description
00
Parameter storage unit PSU not found
001
Safety parameters not OK
02
Flow temperature sensor short circuited
9 Troubleshooting
7611444 - v06 - 04032019