Product name
AWHP 4.5MR–
EMC 24/28 MI
HYBRIDE
AWHP 6MR3–
EMC 24/28 MI
HYBRIDE
AWHP 8MR–
EMC 24/28 MI
HYBRIDE
T
j
= bivalent temperature
COPd
-
or
%
3.46
3.40
3.49
T
j
= operation limit temperature
COPd
-
or
%
1.84
1.52
1.63
Operation limit temperature for air-to-water
heat pumps
TOL
°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
80
80
80
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
0.049
Stand-by
P
SB
kW
0.012
0.018
0.018
Crankcase heater mode
P
CK
kW
0.055
0.055
0.055
Supplementary heater
Psup
kW
4.0
4.8
5.8
Type of energy input
Gas
Gas
Gas
Other specifications
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
42 – 61
41 – 63
41 – 64
Annual energy consumption under average
conditions
Q
HE
kWh
GJ
4045
6
4312
7
5859
8
Annual energy consumption under colder con
ditions
Q
HE
kWh
GJ
4564
3
4236
3
6548
5
Annual energy consumption under warmer
conditions
Q
HE
kWh
GJ
1299
0
1544
0
1904
0
Rated air flow rate, outdoors for air-to-water
heat pumps
—
m
3
/h
2100
2100
3300
Declared load profile
XL
XL
XL
Daily electricity consumption
Q
elec
kWh
0.177
0.177
0.177
Annual electricity consumption
AEC
kWh
38
38
38
Water heating energy efficiency
ƞ
wh
%
86.00
86.00
86.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
0.000
Annual fuel consumption
AFC
GJ
17
17
17
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
See
The back cover for contact details.
3.2.5
Hydraulic module circulating pump
Important
The benchmark for the most efficient circulating pumps is EEI ≤
0.20.
3 Technical specifications
7611444 - v06 - 04032019
21