12 Appendix
12.1 Product fiche
Tab.42 Product sheet for heat pump combination heaters
AWHP
4.5MR–EMC
24/28 MI
HYBRIDE
AWHP 6MR–
EMC 24/28 MI
HYBRIDE
/ AWHP
6MR3–EMC
24/28 MI
HYBRIDE
AWHP 8MR–
EMC 24/28 MI
HYBRIDE
Space heating - Temperature application
No
No
No
Water heating - Declared load profile
XL
XL
XL
Seasonal space heating energy efficiency class under average
climate conditions
A
++
A
++
A
++
Water heating energy efficiency class under average climate
conditions
A
A
A
Rated heat output under average climate conditions
(Prated or
Psup)
kW
8
8
11
Space heating - Annual energy consumption under average cli
mate conditions
kWh
GJ
4045
6
4312
7
5859
8
Water heating - Annual energy consumption under average cli
mate conditions
kWh
GJ
38
38
38
Seasonal space heating energy efficiency under average cli
mate conditions
%
136
133
135
Water heating energy efficiency under average climate condi
tions
%
86.00
86.00
86.00
Sound power level L
WA
dB
42
41
41
Ability to off-peak hours functioning
No
No
No
Rated heat output, under colder - warmer climate conditions
kW
6 – 4
6 – 5
9 – 6
Space heating - Annual energy consumption, under colder -
warmer climate conditions
kWh
GJ
4564 – 1299
3 – 0
4236 – 1544
3 – 0
6548 – 1904
5 – 0
Water heating - Annual energy consumption, under colder -
warmer climate conditions
kWh
39 – 39
17 – 17
38 – 39
17 – 1717
38 – 3939
17 – 17
Seasonal space heating energy efficiency, under colder - warm
er climate conditions
%
122 – 167172 122 – 166166
125 – 169
Water heating energy efficiency, under colder - warmer climate
conditions
%
86.00 – 86.00 86.00 – 86.00
86.00 – 86.00
Sound power level L
WA
outdoors
dB
61
63
64
(1) If applicable.
(2) Electricity
(3) Fuel
See
For specific precautions on assembly, installation and
maintenance: see the chapter on Safety Instructions.
12.2 Product fiche - Temperature Controls
Tab.43 Product fiche for the Temperature controls
IniControl 2
Class
II
Contribution to space heating energy efficiency
%
2
12 Appendix
7611444 - v06 - 04032019