Parameter
Description
Factory setting
AP073
Outdoor temperature: upper limit for heating
SUMMER / WINTER set point switch:
Can be set from 15 °C to 30.5 °C
22
AP074
The heating is stopped. Hot water is maintained. Force Summer Mode
SUMMER override:
0 = off
1 = on
0
AP082
Automatic change between summer and winter time
0 = Off
1 = On
0
HP : Heat-pump Parameters = Heat pump parameters
Tab.24
Parameter
Description
Factory setting
HP062
Energy cost in Hybrid electricity cost in high tarif
Can be set from 0.01 to 2.50 €/kWh
0.13 €/kWh
HP063
Energy cost in Hybrid electricity cost in low tarif
Can be set from 0.01 to 2.50 €/kWh
0.09 €/kWh
HP064
Cost of fossil energy (oil or gas) - price per litre or per m3
Cost of fossil energy (oil or gas) - price per litre or per m
3
Can be set from 0.01 to 2.50 €/kWh
0.90 €/kWh
6.2.4
User \HMI menu
Tab.25 AP : Appliance Parameters = Appliance parameters
Parameter
Description
Factory setting
AP067
BKL backlighting
0 = off after 3 minutes of inactivity on the control panel
1 = on
0
AP103
Setting the LANGUAGE:
0 = no language
FR = French
NL = Dutch
EN = English
DE = German
ES = Spanish
IT = Italian
PL = Polish
PT = Portuguese
FR
AP104
Setting the CONTRAST:
Can be set from 0 to 3
3
AP105
Selecting the UNIT:
0 = °C
1 = °F
0
AP082
Changing the DLS summer/winter timer:
0 = off
1 = on
0
6.2.5
HP parameters in the User menu
HP : Heat-pump Parameters = Heat pump parameters
6 Settings
7611444 - v06 - 04032019
35