Outdoor unit
Associated/compatible indoor units
AWHP 16 MR-2
MIV-S 11-16/EM
MIV-S 11-16/EMI
MIV-S 11-16/ET
MIV-S 11-16/ETI
MIV-S 11-16/H
MIV-S 11-16/HI
AWHP 16 TR-2
MIV-S 11-16/EM
MIV-S 11-16/EMI
MIV-S 11-16/ET
MIV-S 11-16/ETI
MIV-S 11-16/H
MIV-S 11-16/HI
3.2.2
Heat pump
The specifications are valid for a new appliance with clean heat
exchangers.
Maximum operating pressure: 0.3 MPa (3 bar)
Tab.3
Indoor unit technical specifications
Specifications
AWHP MIV-S
Operating temperature range
+7 °C to +30 °C
Bluetooth frequency band
2400 – 2483.5 MHz
Bluetooth power
+5 dBm
Tab.4
Outdoor unit conditions of use
Limit operating temperatures
AWHP 4.5 MR
AWHP 6 MR-3
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Water in heating mode
+18 °C/+55 °C
+18 °C/+60 °C
+18 °C/+60 °C
+18 °C/+60 °C
+18 °C/+60 °C
Outdoor air in heating mode
-15 °C/+35 °C
-15 °C/+35 °C
-20 °C/+35 °C
-20 °C/+35 °C
-20 °C/+35 °C
Water in cooling mode for the non-
insulated models
+18 °C/+25 °C
+18 °C/+25 °C
+18 °C/+25 °C
+18 °C/+25 °C
+18 °C/+25 °C
Water in cooling mode for the insu
lated models
+7 °C / +25 °C
+7 °C / +25 °C
+7 °C / +25 °C
+7 °C / +25 °C
+7 °C / +25 °C
Outdoor air in cooling mode
+7 °C/+46 °C
+7 °C/+46 °C
+7 °C/+46 °C
+7 °C/+46 °C
+7 °C/+46 °C
Tab.5
Heating mode: outdoor air tempe7 °C, water temperature at the 35 °C. Performances in accordance
with EN 14511-2.
Measurement type Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output
kW
4.60
5.82
7.9
11.39
11.39
14.65
14.65
Coefficient of Per
formance (COP)
5.11
4.22
4.34
4.65
4.65
4.22
4.22
Absorbed electri
cal power
kWe
0.90
1.38
1.82
2.45
2.45
3.47
3.47
Nominal water flow
rate (ΔT = 5 K)
m
3
/hour
0.88
1.00
1.53
1.96
1.96
2.53
2.53
3 Technical specifications
12
AWHP MIV-S
7748711 - v03 - 08062020