6.2 Setting the parameters
6.2.1 Modifying the User parameters
Note
The name of the PCB is displayed. Check that it is actually the
PCB on which the setting must be made.
The parameters in the User menu can be modified by the user to meet his
central heating and domestic hot water comfort requirements.
Caution
Modification of the factory settings may impair operation of the ap
pliance.
1. Access the User menu.
2. Select the desired parameter by pressing or to scroll through
the list of parameters that can be adjusted.
3. Confirm the selection by pressing
.
4. Modify the value of the parameter by pressing or .
5. Confirm the new value of the parameter by pressing
.
6. Go back to the main display by pressing
h
.
6.2.2 Activating the cooling function
Note
The name of the PCB is displayed: check that it is actually the
PCB on which the setting must be made.
1. Access the User menu.
2. Select the AP015 cooling parameter by pressing the or key
and confirm by pressing the
key.
3. Select cooling function shut-down by pressing the key and con
firm by pressing the
key.
4. Go back to the main display by pressing
h
.
Fig.35 Displaying the User menu
MW-5000040-3
Fig.36 Cooling function
MW-6000365-1
Fig.37 Confirmation
MW-6000366-1
6 Settings
38
MIV-4
7623755 - v02 - 03072015