Parameters
Comfort period / Loading enabled
Factory setting
Customer setting
Prog AUX
Monday:
Tuesday:
Wednesday:
Thursday:
Friday:
Saturday:
Sunday:
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
Prog BUFF.TANK
Monday:
Tuesday:
Wednesday:
Thursday:
Friday:
Saturday:
Sunday:
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
6:00-22:00
#SETTING menu - User Level
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.21 Menu #SETTING
Parameters
Description
Factory setting
Customer setting
SUM/WIN BAND
Neutral band in which the heat pump is deactivated.
Can be set from 0 to 10°C.
4°C
CONTRAST DISP.
Adjusting the display contrast
BACK LIGHT
COMFORT : the screen is illuminated continuously in day
time periods
ECO : the screen is illuminated for 2 minutes whenever a
key on the control panel is pressed
ECO
SUM/WIN
Outside temperature above which the heating will be shut
down:
OFF : The heating is never shut down automatically.
Can be set from 15 to 30°C:
The heating pumps are shut down.
The heat pump only starts up for domestic hot water or
cooling needs, if the function is enabled.
The
symbol is displayed.
The symbol is displayed if the cooling function is ena
bled,
22°C
CALIBR.OUT
Outside sensor calibration
Is used to correct the outside temperature information.
Outside tempera
ture
OFFSET ROOM A
Room temperature offset on circuit A.
Make this setting 2 hours after switching on, when the room
temperature has stabilised.
Can be set from -5 to +5°C.
0
OFFSET ROOM B
Room temperature offset on circuit B.
Is used to set a room temperature offset.
Make this setting 2 hours after switching on, when the room
temperature has stabilised.
Can be set from -5 to +5°C.
0
OFFSET ROOM C
Room temperature offset on circuit C.
Is used to set a room temperature offset.
Make this setting 2 hours after switching on, when the room
temperature has stabilised.
Can be set from -5 to +5°C.
0
6 Settings
26
GSHP
7611407 - v07 - 14022022