Parameters
Description
Factory setting
Customer setting
WATER T.NIGHT.C
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to circuit C.
Can be set from 10 to 80°C.
10°C
WATER T.NIGHTAUX
Temperature set point in NIGHT mode for a second domestic
hot water tank connected to the auxiliary circuit.
Can be set from 10 to 80°C.
10°C
MODE menu - User Level
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.15 Menu MODE
Parameters
Description
Factory setting
Customer setting
FORCE AUTO
An operating mode override is activated on the remote con
trol (optional).
To force every circuit in AUTOMATIC mode, select the value:
ON.
AUTOMATIC
The temperatures switch automatically from DAY mode to
NIGHT mode according to the setting on the #TIME
PROGRAM menu.
DAY
DAY mode is forced:
DAY -> : until the set time
DAY 7/7 : at all times 24/7
Current time + 1
hour
NIGHT
NIGHT mode is forced:
NIGHT -> : until the set time
NIGHT 7/7 : at all times 24/7
Current time + 1
hour
HOLIDAYS
Frost protection mode is active:
DAYS ANTIFREEZ : number of days' holiday
STOP HEAT : heating shut-down date
RE-START : heating restart date
The start and end days and the number of days are calcula
ted in relation to each other.
Current date + 1
hour
SUMMER
SUMMER mode is forced:
the heating is shut down
domestic hot water continues to be produced
COLD
COOLING mode is forced without taking into account the
outside temperature or the SUM/WIN parameter.
MANUEL
The appliance operates according to the set point settings.
All of the pumps operate.
Possibility of setting the set point by simply turning the but
ton.
Domestic Hot Water menu - User Level
Tab.16 Domestic Hot Water menu (
)
Parameters
Description
Factory setting
AUTOMATIC
Domestic hot water production is determined by the setting in the #TIME
PROGRAM menu.
COMFORT 7/7
Domestic hot water production is forced at all times: seven days a week.
Current time + 1
hour
COMFORT ->
Domestic hot water production is forced until the set time:
Current time + 1
hour
6 Settings