Tab.7
Performances for a water/water system (10°C/7°C and 30°C/35°C), in accordance with NF EN 14511–1
Caution
The tests to evaluate the performance of the heat pumps were run without a barrage exchanger. If that component
is used in the installation, performances are reduced and the specifications stated are no longer certified.
Caution
These performance tests have been carried out in order to comply with the requirements of the standard. Always
use a barrage exchanger (water/water) to protect the exchanger.
Measurement
type
Unit
GSHP 5
MR-E
GSHP 5
TR-E
GSHP 9
MR-E
GSHP 9
TR-E
GSHP
12 MR-E
GSHP
12 TR-E
GSHP
15 TR-E
GSHP
19 TR
GSHP
27 TR
Power supply
V
(~50 Hz)
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
400
three-
phase
400
three-
phase
400
three-
phase
Coefficient of
performance
(COP)
-
5.64
5.64
5.52
5.52
5.30
5.30
5.38
5.14
4.71
Absorbed elec
trical power
kW
1.23
1.23
2.19
2.19
2.93
2.93
3.88
5.12
7.01
Application flow
rate
m
3
/h
1.28
1.28
2.23
2.23
2.86
2.86
3.84
4.85
6.08
Heat output
kW
6.95
6.95
12.13
12.1
15.54
15.54
20.87
26.3
33
Tab.8
Performances for a water/water system (10°C/7°C and 40°C/45°C), in accordance with NF EN 14511–1
Caution
The tests to evaluate the performance of the heat pumps were run without a barrage exchanger. If that component
is used in the installation, performances are reduced and the specifications stated are no longer certified.
Caution
These performance tests have been carried out in order to comply with the requirements of the standard. Always
use a barrage exchanger (water/water) to protect the exchanger.
Measurement
type
Unit
GSHP 5
MR-E
GSHP 5
TR-E
GSHP 9
MR-E
GSHP 9
TR-E
GSHP
12 MR-E
GSHP
12 TR-E
GSHP
15 TR-E
GSHP
19 TR
GSHP
27 TR
Power supply
V
(~50 Hz)
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
400
three-
phase
400
three-
phase
400
three-
phase
Coefficient of
performance
(COP)
-
4.25
4.25
4.37
4.37
4.19
4.19
4.27
4.12
3.9
Absorbed elec
trical power
kWe
1.54
1.54
2.67
2.67
3.55
3.55
4.69
6.11
8.24
Heat output
kW
6.55
6.55
11.68
11.68
14.89
14.89
20.02
25.1
32.1
Tab.10 Common specifications
Measurement
type
Unit
GSHP 5
MR-E
GSHP 5
TR-E
GSHP 9
MR-E
GSHP 9
TR-E
GSHP
12 MR-E
GSHP
12 TR-E
GSHP
15 TR-E
GSHP
19 TR
GSHP
27 TR
Power supply
V
(~50 Hz)
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
400
three-
phase
400
three-
phase
400
three-
phase
Start-up amper
age
A
<30
<30
<30
<30
<30
<30
<30
<30
<30
Maximal amper
age
A
12.8
4.8
22.8
7.4
27.9
9.7
13
15.3
21.6
Sound output
dB(A)
49
49
53
53
52
52
51
53
50
Refrigerant
R410A
kg
1.50
1.50
1.70
1.70
1.80
1.80
2.50
2.54
3.18
3 Technical specifications
12
GSHP