Instruction Manual
Negative Pressure Unit green dec
Version 1
Page 51
Device
Recommended filter change at
110 V
230 V
G 50 / G 55
approx. 700 Pascal
approx. 800 Pascal
G 100
approx. 700 Pascal
approx. 1000 Pascal
G 200
approx. 700 Pascal
approx. 1100 Pascal
G 300
approx. 700 Pascal
approx. 1100 Pascal
G 400
---
approx. 1200 Pascal
G 500
---
approx. 1300 Pascal
8.1.2. Control SRE +
The following table shows the display values for a recommended filter change. If the display
reaches this value, please replace first or intermediate filter first. If the display value drops
by 100 Pascal or more, the unit can continue to operate. If the value drops by less than
100 pascals, the HEPA filter must be renewed.
Device
Recommended filter change at
110 V
230 V
G 100
approx. 700 Pascal
approx. 1000 Pascal
G 200
approx. 700 Pascal
approx. 1100 Pascal
G 300
approx. 700 Pascal
approx. 1100 Pascal
G 400
---
approx. 1200 Pascal
G 500
---
approx. 1300 Pascal
absolute pressure