Instruction Manual
Negative Pressure Unit green dec
Version 1
Page 31
Um Schäden zu vermeiden kann in der Betriebsart „Automatikbetrieb Volumenstrom“ der
Volumenstrom durch die Eingabe eines maximal erlaubten Unterdrucks begrenzt werden
(max -Pa).
Durch Tippen auf den Button „Close“ wird das Einstellungsmenü verlassen.
7.2.7. Stand-by mode
A negative pressure unit with SRE connect can be operated as a stand-by device
(replacement device). If this function is activated, the device switches itself on
automatically if the negative pressure falls below a predefined negative pressure (for
example, if the used negative pressure unit fails).
The stand-by mode is activated in the settings menu by tapping the "Standby" button.
When activated, the button is shown in green.
The device switches on when the negative pressure entered in the "min -Pa" field is
undershot.
A delay for switching on can be entered in the "delay time on" field (maximum 90
seconds).
By tapping the "Close" button the settings menu is exited.