5.1.7 Serial Port Protocol Selection
Used to select which serial protocol the SVR is to use when sending
information to the serial port . Pressing the SEL button switches
between Sr1 and Sr2 .
Figure 5.1.7a
Serial Port Mode
Figure 5.1.7b
Sr1 selection
Figure 5.1.7c
Sr2 selection
Sr1 = SSS .SS<CR> (Where SSS .SS is the averages speed or "running
average" and <CR> is a carriage return .)
Sr2 = AAA,RRR .RR,SSS .SS<CR> (Where AAA is the confidence
number ranging from 004 to 999 with 004 being the lowest
confidence number and 999 being the most confident) . RRR .RR
is the present speed or the current speed measured . SSS .SS is the
averages speed or "running average" . <CR> is a carriage return .
5.1.8 Serial Update Rate
Used to set the update rate for the SVR . Can be set to allow the SVR
to update every 100 ms, 300 ms, 500 ms, 800 ms or 999 ms .
Figure 5.1.8